5
1.3 Numeric Entries:
Once you have entered Setup and Calibration mode, (as described on the previous
page) some entries may require entering a numeric value.
To enter a numeric value:
1.
Press and release the
lb/kg
key to move into the desired menu field.
2.
Press and release the
ZERO
key, the first digit will begin to flash.
3.
Use the up and down arrow keys to increase or decrease the value of this
digit until you reach the desired value.
4.
Press the
TARE
key to move to the next digit and repeat step 3.
When you are satisfied with the value of each digit press the
PRINT/ENTER
key to
save your entry and return to the menu.
1.4 Setup Parameters:
To begin press and hold this key until the Parameter (
P xxx
) Event counter is displayed,
then release. Immediately after
CodE
is displayed, enter in sequence (within 5 seconds)
TARE
,
lb/kg
,
GRS/NET
, and
PRINT/ENTER
. The display will indicate
ScAlE
and you are now in Setup
& Calibration mode.
Note: P xxx and C xxx are event counters that will increment each time one or more
Changes are made to the scale Scale or Calibration Parameters.
With the display indicating
ScAlE
, press the
GRS/NET
key to move down to change a
parameter. This allows the operator to change any one of the Scale Parameters S1 thru S18. For
example, press the
GRS/NET
key to move down until
S2
is displayed,
S2
is used to set the
capacity of the scale. Press the
lb/kg
key to move right into the
S2
parameter. The current capacity
will be displayed. Press the
ZERO
key; the first digit will begin flashing. Enter the new capacity
using the steps described in section 1.4 shown at the top of the page. Once you have the capacity
entered, press the
PRINT/ENTER
key to enter the value and return to
S2
.
The same steps can be followed to enter the count by. Press the
GRS/NET
key to move
down until S3 is displayed. Press the
lb/kg
key to move right into the
S3
parameter. The current
Count By will be displayed. Use the up and down arrow keys to increase or decrease the value.
Use the left and right arrow keys to adjust the decimal point. When the desired Count By is
entered, press the
PRINT/ENTER
key to enter the value and return to
S3
.