1.3
Scale Menu Definitions:
S1
NTEP (Ntep): Maximum divisions limited to 5000.
scale negative message is displayed if the gross weight
goes more than 10 divisions below zero. If a capacity and
count by of more than 5000 divisions is selected
ERR d
will be displayed and you will be returned to
S2
to
select a new capacity or count by.
Angle: Enables angle correction for Legal For Trade
lift truck scales.
No: 20,000 maximum division limits and no scale negative tests.
S2
Capacity 1 to 950,000 pounds (5000).
S3
Count By .001, .01, .1, (1), 10, 100,
.002, .02, .2, 2, 20, 200
.005, .05, .5, 5, 50, 500
S4
Over load (105%) of scale capacity or user entered value.
S5
Zero Limit (100%) or 1.9% of scale capacity.
S6
Filter 0 - 7 (3) 0 is the fastest response or least filtering and 7 is
the slowest response or most filtering
S7
Motion Band 1 to 99 updates (2) the weight display must be
stable within the selected number of updates
for the motion indicator to be turned off.
S8
Motion Delay 0 to 99 updates (4) the weight display must be
within the motion band for the selected number
of updates for the motion indicator to be turned off.
S9
Motion (Normal): When the scale is in motion the motion LED will
Display light.
Blank: When the scale is in motion the display will be
blanked out.
Dashes: When the scale is in motion the display will show
all Dashes.
S10
Zero Band 1 to 99 divisions (2) the weight display must return
to Zero within the selected number of divisions to
to be considered Zero.
MANUAL P/N: 5999-1021-01 (8/11)