Installation
Secure every second reflector overlap together with a minimum of 2 - #8 x 3/8" long screws (not
supplied), and secure reflector to the reflector bracket at this point by tightening down #8 x 1¼"
screws supplied with reflector brackets (Figure 16). The remaining reflector overlap joints and
reflector brackets are left loose to accommodate system movement.
Figure 16: Reflector Supports Installation and Reflector Overlap
Install End Cap as shown in Figure 4 and Figure 17.
Figure 17: Reflector End Cap Installation
Insert End Cap into Reflector
and Secure it with #8 x 3/8" Screws
Secure every
SECOND
reflector
overlap with a minimum of 2
#8 x 3/8" long screws
on each side
Secure reflector to reflector
bracket by tightening
#8 x 1 1/4" long screws every