Chapter 8: Troubleshooting
Testing a TDM link
Page 8-19
Performing a TDM loopback test
The loopback test allows a TDM data stream to be looped back at the copper or wireless
interface. A typical T1 or E1 installation test includes a copper loopback on the local unit
followed by a wireless loopback on the remote unit.
Note
The TDM Configuration page is only available when the TDM interface is enabled and
the unit is rebooted (
Procedure:
•
Select menu option System > Configuration > TDM Configuration (
•
Set the TDM Channel Loopback n attribute (where “n” is in the range 1 to 8) to Copper or
Wireless (
).
•
Click Submit Updated TDM Configuration.
•
Perform loopback tests. The System Summary page displays alarms indicating the
presence of loopbacks on each affected TDM channel (
).
•
Set the TDM Channel Loopback n attribute (where “n” is in the range 1 to 8) to None (
).
•
Click Submit Updated TDM Configuration.
Checking for 1000BASE-T operation
If the ODU port has negotiated a link at 100BASE-T, the NIDU will not send or receive TDM data
and will not bridge customer data traffic. Check that the Ethernet drop cable between the ODU
and the PSU, and the network cable between the PSU and the NIDU have successfully
negotiated operation at 1000BASE-T. On the System Status page, review Main PSU Port Speed
and Duplex (
) and confirm that it is set to 1000 Mbps Full Duplex.
Содержание PTP 670 Series
Страница 1: ...F Cambium PTP 670 Series User Guide System Release 670 02 50 ...
Страница 349: ...Chapter 5 Installation Installing an SFP Ethernet interface Page 5 52 Correct Incorrect ...
Страница 405: ...Chapter 6 Configuration and alignment System menu Page 6 46 Figure 151 LAN Configuration page PTP topology TDM support ...
Страница 406: ...Chapter 6 Configuration and alignment System menu Page 6 47 Figure 152 LAN Configuration page PTP topology SFP support ...
Страница 408: ...Chapter 6 Configuration and alignment System menu Page 6 49 Figure 154 LAN Configuration page HCMP topology ...
Страница 416: ...Chapter 6 Configuration and alignment System menu Page 6 57 Figure 156 QoS Configuration page IP MPLS ...
Страница 445: ...Chapter 6 Configuration and alignment Management menu Page 6 86 Figure 173 Time Configuration page SNTP enabled ...
Страница 551: ...Chapter 7 Operation System statistics Page 7 64 Figure 250 Main Port Counters page when main port is bridging traffic ...