![Cambium PTP 670 Series Скачать руководство пользователя страница 388](http://html.mh-extra.com/html/cambium/ptp-670-series/ptp-670-series_user-manual_485665388.webp)
Chapter 6: Configuration and alignment
Installation menu
Page 6-29
Attribute
Meaning
Link Symmetry
Only displayed when Wireless Topology is set to Point To Point and
Master Slave Mode is set to Master.
Adaptive: Allows link symmetry to vary dynamically in response to
offered traffic load. This is not supported in the following cases:
•
Where radar avoidance is mandated in the region.
•
Link Mode Optimization is set to TDM Traffic.
“5 to 1”, “3 to 1, “2 to 1”, “1 to 1”, “1 to 2”, “1 to 3” or “1 to 5”: There is
a fixed division between transmit and receive time in the TDD frame of
the master ODU. The first number in the ratio represents the time allowed
for the transmit direction and the second number represents the time
allowed for the receive direction. The appropriate matching Link
Symmetry is set at the slave ODU automatically. For example, if Link
Symmetry is set to “2 to 1” at the master ODU, then the slave ODU will
be set automatically as “1 to 2”. In this example, the master-slave
direction has double the capacity of the slave-master direction.
When TDM is enabled (
), Link
Symmetry is limited to “1 to 1”.
Spectrum
Management
Control
PTP topology
In regions that do not mandate DFS (radar detection), the options are:
DSO
Fixed Frequency
In regions that mandate DFS (radar detection), the options are:
DFS
DFS with DSO
This attribute is disabled if the regulatory requirement is fixed frequency
only.
PTP topology
At the Master ODU, the only option is:
Fixed Frequency
At the Slave ODU, the options are:
DSO
Fixed Frequency
Extended Spectrum
Scanning
Enables scanning of the entire frequency spectrum supported by the
device (4800 MHz to 5875 MHz, or 4900 MHz to 6050 MHz).
Disabled: The extended Spectrum Scanning is disabled.
Enabled: The extended Spectrum Scanning is enabled.
Caution
Extended Spectrum Scanning decreases DSO performance. Do
not leave Extended Spectrum Scanning enabled during normal
operation.
Содержание PTP 670 Series
Страница 1: ...F Cambium PTP 670 Series User Guide System Release 670 02 50 ...
Страница 349: ...Chapter 5 Installation Installing an SFP Ethernet interface Page 5 52 Correct Incorrect ...
Страница 405: ...Chapter 6 Configuration and alignment System menu Page 6 46 Figure 151 LAN Configuration page PTP topology TDM support ...
Страница 406: ...Chapter 6 Configuration and alignment System menu Page 6 47 Figure 152 LAN Configuration page PTP topology SFP support ...
Страница 408: ...Chapter 6 Configuration and alignment System menu Page 6 49 Figure 154 LAN Configuration page HCMP topology ...
Страница 416: ...Chapter 6 Configuration and alignment System menu Page 6 57 Figure 156 QoS Configuration page IP MPLS ...
Страница 445: ...Chapter 6 Configuration and alignment Management menu Page 6 86 Figure 173 Time Configuration page SNTP enabled ...
Страница 551: ...Chapter 7 Operation System statistics Page 7 64 Figure 250 Main Port Counters page when main port is bridging traffic ...