Overview and TD-90 modes of operation
8
l
Master 1 Scan Align: 90° scan with 5° steps and 5 second dwell time. The Master records signal
strength levels at all 18 steps and returns to the highest recorded level.
l
Slave 1 Scan Align: Waits for Master command to move, 90° scan with 5° steps and 5 second dwell
time. The Slave records signal strength levels at all 18 steps and returns to the highest level
recorded. Reports scan complete back to master.
l
Master 2 Scan Align: 45° scan with 5° steps and 5 second dwell time. Master records signal level at
each step returns to the highest recorded level.
l
Slave 2 Scan Align: Waits for Master command to move, 45° scan with 5° steps and 5 second dwell
time. Slave records signal level at each step returns to the highest recorded level. Reports scan
complete back to master.
l
Master 1 peak: Master 1 performs first step peak function.
l
Slave 1 peak: Waits for Master command to move, performs first step peak function, reports peak
complete back to master.
l
Master 2 peak: Master performs final step peak function.
l
Slave 2 peak: Waits for Master command to move, performs second step peak function, reports
peak complete back to master.
Содержание TD-90 Series
Страница 1: ...USER GUIDE TD 90 Series ...
Страница 4: ...4 TD 90 Errors 53 System Recovery 61 Contacting Cambium Networks 62 ...
Страница 15: ...TD 90 Pre Configuration 15 Figure 10 Step 10 Optional Mode 1 Setup ...
Страница 26: ...TD 90 Mechanical and Electrical Interfaces 26 Right Side View of TD 90 ...
Страница 35: ...Web Based User Interface 35 ...
Страница 39: ...Web Based User Interface 39 ...
Страница 41: ...Web Based User Interface 41 ...
Страница 46: ...Web Based User Interface 46 ...
Страница 48: ...Web Based User Interface 48 ...
Страница 52: ...Web Based User Interface 52 ...
Страница 54: ...Web Based User Interface 54 ...