background image

 

PTP 820C Quick Start Guide 

 

Page 12 

 

To connect the PoE Injector cables 

 

The total length of the cable between the PTP 820C port and the 
Switch/Router the device is connected to should not exceed 100m/328ft. 
This length includes the connection between the PTP 820C and the PoE 
Injector (

X1 + X2

 

 100m/328ft in the figure to the right). 

 

The length of the cable connecting the customer equipment to the PoE 
injector should not be longer than 10m (according to ANSI/TIA-568 
standard). 

PT

820

C

X2

DC

X1

CSR

Содержание PTP 820C

Страница 1: ...QUICK START GUIDE PTP 820C System Release 9 0...

Страница 2: ...al polarization direct mount link with Multi carrier ABC and XPIC For detailed instructions of all supported PTP 820C link types refer the PTP 820C Installation Guide For detailed instructions of soft...

Страница 3: ...PTP 820C Quick Start Guide Page 3 PoE Injector PoE Injector Interfaces...

Страница 4: ...are installation required Hardware configuration including the type of mediation devices required differs for different configurations For other configurations besides the 2 0 dual polarization direct...

Страница 5: ...two separate LC connectors one for each fiber Remove the gland cap and rubber from the gland body Slide the gland cap into the cable Slide the rubber into the cable Insert the fibers with the connect...

Страница 6: ...een the gland and the radio unit and hand tighten the gland cap Secure the cable to the gland using a tie wrap 2 3 5 6 4 Connect the CAT5E cable to the PTP 820C 1 Insert the CAT5E cable into the gland...

Страница 7: ...the gland Insert the power cable wires into the power connector Match to the 0V wire and to the 48V wire Plug the power cable with connector into the PTP 820C power connector Hand tighten the gland t...

Страница 8: ...ounding is required for optical SFP cables External shielded CAT5E cable should be grounded to the antenna tower at the top next to the PTP 820 unit and the bottom of the external run and every 50m us...

Страница 9: ...X70 1 2 Drill two 6mm diameter holes with 100mm between the center of the holes Insert the anchors with the bolts place the washers on the bolts and tighten the nuts 3 To mount a PoE Injector on a pol...

Страница 10: ...PoE Injector on a 19 rack Mount the Injector to a 19 rack using a 19 rack adaptor 1 2 Mount the Injector on the adaptor through the wall mounting holes using M6 screws and washers Mount the adaptor to...

Страница 11: ...les using M6 screws and washers 4 2 Connect ETSI adapting ears to a 19 rack adaptor using four M6 screws Mount the 19 rack adaptor with the ETSI ears on the ETSI rack using four M6 screws and cage nut...

Страница 12: ...er the device is connected to should not exceed 100m 328ft This length includes the connection between the PTP 820C and the PoE Injector X1 X2 100m 328ft in the figure to the right The length of the c...

Страница 13: ...n the 2 lugs of the GND cable and verify that the result is 0 2 ohms Notes The unit s earthing screw terminal shall be permanently connected to protective earth in a building installation in accordanc...

Страница 14: ...PTP 820C grounding cable The order in which you place the two cables is not important Connecting to the Unit 1 Connect your laptops LAN port to the MGT port on the PTP 820C 2 Configure an IP address...

Страница 15: ...ation page opens Select IPv4 or IPv6 The unit will use the selected protocol when initiating communications Description of unit optional You can enter an IP address in IPv4 format use the IP address f...

Страница 16: ...EMS displays a yellow background and an activation key violation warning After a 48 hour grace period all other alarms are hidden until the capacity and features in use are brought within the activati...

Страница 17: ...ge 1 of the 2 0 Quick Configuration wizard opens 1 2 3 Select an Ethernet interface or LAG for the link Click Create LAG to open a wizard that guides you through the steps to create a LAG Select the A...

Страница 18: ...ars instead of these fields Select the ACM profile for the radio in the Profile field If you selected Adaptive in the Operational Mode field enter the maximum and minimum profiles for the script in th...

Страница 19: ...PTP 820C Quick Start Guide Page 19 7 Review the parameters and click Submit to complete configuration of the link After you click Submit the unit is reset...

Страница 20: ...Note that the voltage measured at the BNC port is not accurate and should be used only as an aid Verify that the Radio Bit Error Rate BER is 10E 11 or higher If working with ATPC verify that ATPC is...

Страница 21: ...link to maximize the XPI Adjust the OMT by rotating the OMT and its attached ODU on the back of the antenna Loosen the four bolts that connect the OMT to the antenna Move the OMT in small increments...

Страница 22: ...t from Cambium Networks or a Cambium distributor Cambium Networks warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and wo...

Страница 23: ...rate in licensed unlicensed and defined use frequency bands including specific FIPS 140 2 solutions for the U S Federal market Ruggedized for 99 999 availability our PTP solutions have an impeccable t...

Отзывы: