ULP Wired Mini 

User manual

5  Communication Protocols

UART Sentences

MWV Wind Speed and Angle

 1 2 3 4 5

 | | | | |

$--MWV,x.x,a,x.x,a*hh

1) Wind Angle, 0 to 360 degrees

2) Reference, R = Relative, T = True

3) Wind Speed

4) Wind Speed Units, K/M/N

5) Status, A = Data Valid

6) Checksum

MWV Sentence 4800bps 8N1

6  General information

General recommendations

Regarding mounting the unit, align the north mark (the circle on the side) of the ULP Wired 

Mini towards the north. Make sure to install the sensor in a location 

free from anything that 

obstructs the flow of wind to the sensors within a 2 meter radius

.

Maintenance and repair

The ULP Wired Mini does not require great maintenance thanks to the lack of the moving 

parts in this new design.Transducers must be kept clean and aligned. Impacts or inco-

rrect impulsive handling may lead to transducers misalignment. The space around the 

transducers must be empty and clean. Dust, frost, water, etc... will make the unit stop wor-

king. The ULP Wired Mini can be wiped clean with a damp cloth being careful to not touch 

the transducers. 

Warranty

This warranty covers the defects resulting from defective parts, materials and manufac-

turing, if such defects are revealed during the 24 months after the purchase date. Warran-

ty is void in case of non-following the instructions of use, repair or maintenance without 

written authorisation. 

Any wrongful use given by the user will not incur in any responsibility on part of Calypso 

Instruments. Therefore, any harm caused to the ULP Wired Mini by a mistake will not be 

covered by the waranty. Using assembly elements different from those delivered with the 

product will void the warranty. Changes on transducers position/alignment will void any 

warranty. For further information please contact Calypso Technical Support through 

[email protected]

 or visit

 www.calypsoinstruments.com

.      

7

Содержание Ultra-Low-Power Ultrasonic Wired Mini

Страница 1: ...ULTRA LOW POWER ULTRASONIC WIRED MINI WIND METER User manual CALYPSO 0809 R English version 1 0 09 3 2023 ULTRASONIC Portable User manual w w w c a l y p s o i n s t r u m e n t s c o m...

Страница 2: ...If you want to know more about our new ULP Ultrasonic Wired Mini wind meter please keep reading or visit our website www calypsoinstruments com...

Страница 3: ...kage Content Technical Specifications Dimensions Weight Power Sensors Wind Information Firmware Product Material Quality Control Configuration Options Communication Protocols General Information Gener...

Страница 4: ...ensing an extensive R D investment We feel very proud to release a unit that requires under 0 4 mA of power at 5V sam pling at 1Hz Different output options available UART I2C 2 Package content The pac...

Страница 5: ...03 08 ULP Wired Mini User manual The ULP Wired Mini has to be connected as shown in this section The ULP Wired Mini has been designed to avoid any mechanical parts to maximize reliability and minimize...

Страница 6: ...TVS diodes The instrument body is built with Polyamide Every single unit is calibrated with accuracy following the same calibration standards for each one in a wind tunnel A Q C report for both wind s...

Страница 7: ...t all the ULP cables except for the brown cable to the converter Insert the USB into the computer open the configurator app select the configuration wanted and follow the instructions on the screen to...

Страница 8: ...misalignment The space around the transducers must be empty and clean Dust frost water etc will make the unit stop wor king The ULP Wired Mini can be wiped clean with a damp cloth being careful to not...

Страница 9: ...Ultra Low Power Ultrasonic Wired Mini wind meter User manual English version 1 0 07 03 2023...

Отзывы: