background image

03/08

03/08

ULP Wired Mini 

User manual

It can be mounted either on a plate (inferior screws).

Mounting Instructions:

The ULP Wired Mini has a small circle on the outside of the main body which is called 

the north mark. The ULP Wired Mini should be mounted with the north mark facing the 

true north.

The ULP Wired Mini is engineered to be a robust device with minimal downtime. Frost, 

rain or snow might affect measurements if it blocks the wave path. The input wires are 

protected by Transient Voltage

Suppression (TVS) diodes. The instrument body is built with Polyamide.

Every single unit is calibrated with accuracy, following the same calibration standards 

for each one in a

wind tunnel. 

A Q/C report for both wind speed and direction is generated and kept in our files. Stan-

dard deviation is checked to guarantee that each unit has been calibrated to the highest 

standards.

 Wind Information

· Wind Speed

· Wind 
Direction

-Sample Rate

Range: 

Accuracy:
Threshold: 

Range: 0 - 359º
Accuracy: ±1º

1 Hz

0.5 - 45 m/s or 0.5 - 25 m/s (1.12 to 56 
mph or 1.12 to 100 mph)
 0.1 m/s at 10 m/s (0.22 in. at 22 mph)
1 m/s (2.24 mph)

Easy mount

- 3 x M4 base female tripod thread        UNC 1/4” - 20

Upgradable via UART/TTL

Firmware

Product Material

Quality Control

5

Содержание Ultra-Low-Power Ultrasonic Wired Mini

Страница 1: ...ULTRA LOW POWER ULTRASONIC WIRED MINI WIND METER User manual CALYPSO 0809 R English version 1 0 09 3 2023 ULTRASONIC Portable User manual w w w c a l y p s o i n s t r u m e n t s c o m...

Страница 2: ...If you want to know more about our new ULP Ultrasonic Wired Mini wind meter please keep reading or visit our website www calypsoinstruments com...

Страница 3: ...kage Content Technical Specifications Dimensions Weight Power Sensors Wind Information Firmware Product Material Quality Control Configuration Options Communication Protocols General Information Gener...

Страница 4: ...ensing an extensive R D investment We feel very proud to release a unit that requires under 0 4 mA of power at 5V sam pling at 1Hz Different output options available UART I2C 2 Package content The pac...

Страница 5: ...03 08 ULP Wired Mini User manual The ULP Wired Mini has to be connected as shown in this section The ULP Wired Mini has been designed to avoid any mechanical parts to maximize reliability and minimize...

Страница 6: ...TVS diodes The instrument body is built with Polyamide Every single unit is calibrated with accuracy following the same calibration standards for each one in a wind tunnel A Q C report for both wind s...

Страница 7: ...t all the ULP cables except for the brown cable to the converter Insert the USB into the computer open the configurator app select the configuration wanted and follow the instructions on the screen to...

Страница 8: ...misalignment The space around the transducers must be empty and clean Dust frost water etc will make the unit stop wor king The ULP Wired Mini can be wiped clean with a damp cloth being careful to not...

Страница 9: ...Ultra Low Power Ultrasonic Wired Mini wind meter User manual English version 1 0 07 03 2023...

Отзывы: