03/08
03/08
ULP Wired Mini
User manual
It can be mounted either on a plate (inferior screws).
Mounting Instructions:
The ULP Wired Mini has a small circle on the outside of the main body which is called
the north mark. The ULP Wired Mini should be mounted with the north mark facing the
true north.
The ULP Wired Mini is engineered to be a robust device with minimal downtime. Frost,
rain or snow might affect measurements if it blocks the wave path. The input wires are
protected by Transient Voltage
Suppression (TVS) diodes. The instrument body is built with Polyamide.
Every single unit is calibrated with accuracy, following the same calibration standards
for each one in a
wind tunnel.
A Q/C report for both wind speed and direction is generated and kept in our files. Stan-
dard deviation is checked to guarantee that each unit has been calibrated to the highest
standards.
Wind Information
· Wind Speed
· Wind
Direction
-Sample Rate
Range:
Accuracy:
Threshold:
Range: 0 - 359º
Accuracy: ±1º
1 Hz
0.5 - 45 m/s or 0.5 - 25 m/s (1.12 to 56
mph or 1.12 to 100 mph)
0.1 m/s at 10 m/s (0.22 in. at 22 mph)
1 m/s (2.24 mph)
Easy mount
- 3 x M4 base female tripod thread UNC 1/4” - 20
Upgradable via UART/TTL
Firmware
Product Material
Quality Control
5