Rejuvenation Series Spas
LTR50001131, Rev. A
Operating
Your Spa
www.calspas.com
10
Operating Your Spa
JETS
S
S
J
J
AUX
UX
X
A
LIG
LIGH
LIGHT
T
H
H
HEAT
AT
AT
JETS
AUX
LIGHT
HEAT
BP500 Electronic Control Operation
These instructions will describe features and options that your particular spa may not be equipped with.
As soon as it appears on the panel, push the
Jet
button once to start the circulation pump. Also, push
the
Aux
button to turn on the Microsilk pump. The
pumps will now be running to facilitate priming.
If the pumps have not primed after two minutes,
and water is not flowing from the jets in the spa,
do not allow the pumps to continue to run. Turn off
the pumps and repeat the process. Note: Turning the
power off and back on again will initiate a new pump
priming session. Sometimes momentarily turning the
pump off and on will help it to prime. Do not do this
more than five times. If the pump(s) will not prime,
shut off the power to the spa and call for service.
Important: A pump should not be allowed to run
without priming for more than two minutes. Under
NO circumstances should a pump be allowed to run
without priming beyond the end of the 4-5 minute
priming mode. Doing so may cause damage to the
pump and cause the system to energize the heater
and go into an overheat condition.
This mode will last for 4-5 minutes or you can
manually exit the priming mode after the pump has
primed.
Regardless of whether the priming mode ends
automatically or you manually exit the priming mode,
the system will automatically return to normal heating
and filtering at the end of the priming mode. During
the priming mode, the heater is disabled to allow
the priming process to be completed without the
possibility of energizing the heater under low-fl ow or
no-flow conditions. Nothing comes on automatically,
but the pump can be energized by pushing the
Jet
button. The circulation pump can be activated by
pressing the
Light
button during Priming Mode.
You can manually exit Priming Mode by pressing a
“Temp” button (Up or Down). Note that if you do not
manually exit the priming mode as described above,
the priming mode will be automatically terminated
after 4-5 minutes. Be sure that the pump(s) have
been primed by this time.
Once the system has exited Priming Mode, the top-side
panel will momentarily display the set temperature
but the display will not show the temperature yet,
as shown below. This is because the system requires
approximately 1 minute of water flowing through
the heater to determine the water temperature and
display it.
Priming Mode
Priming the Pump
The following message will appear on the panel:
Exiting Priming Mode
Содержание Rejuvenation Series
Страница 1: ...LTR50001131 Rev A 1 2 13...