Calsense CS3000 Скачать руководство пользователя страница 8

Calsense 

 

CS3000 Quick Start Guide 

Measuring Flow 

1.

 

From the Main Menu, use 

 

to navigate to 

POCs

 and press 

SELECT

. The POCs menu displays. 

2.

 

Navigate to 

Flow Meters & Master Valves 

and press 

SELECT

. The Flow Meter & Master Valves 

screen displays (Figure 9). The pane on the left displays the POCs attached to this controller 
while the right shows the settings for each. 

 

Figure 9 - Flow Meters & Master Valves screen 

3.

 

Press 

SELECT

 to enter the right side to adjust the schedule. 

4.

 

Use 

←↑→↓

 

to navigate through the screen and 

+

/

 to change values, setting the following 

values: 

 

POC used for

 – Either Irrigation, Non-Irrigation, or Not Used. If there is no flow meter or 

master valve connected to this POC, select Not Used. 

 

Flow Meter

 – The flow meter type. This can be either a Calsense FM series flow meter, 

such as an FM-1.5B, an insertion-style flow meter (model FMBX), or a hydrometer. 

 

Master Valve 

– The master valve type, either Normally Open or Normally Closed. 

5.

 

Press 

NEXT

 to move to the next POC and repeat step 4 to set each POC’s settings. 

6.

 

Once done, press 

BACK

 to return to the Main Menu. 

Manually Watering a Station 

1.

 

From the Main Menu, use 

 

to navigate to 

Manual & Test

 and press 

SELECT

. The Manual & 

Test menu displays. 

 

 

Содержание CS3000

Страница 1: ...V NEXT Selects the Previous or Next menu item 4 SELECT Move the cursor position around in the different programming and reports screens and selects a main menu field or a particular programming field...

Страница 2: ...and time and use to change values to set the current date and time 5 Once the time is correct navigate to and select Set Date Time to save the change 6 Once done press BACK to return to the Main Menu...

Страница 3: ...cally appear The Station Assignment screen displays Figure 3 The pane on the left displays the 2 Station and Moisture Sensor decoders discovered while the right shows each s station assignments Figure...

Страница 4: ...ht a decoder to edit and press SELECT The cursor moves to the Is this POC Decoder In Use field on the right 3 Use to navigate through the screen and the to select whether the decoder is in use and whe...

Страница 5: ...assigned to that group By default the name will automatically take on the plant type head type and exposure Mainline The mainline the stations in this group are physically connected to Plant type The...

Страница 6: ...required press BACK and navigate to and select Add New Group to create additional groups and repeat steps 3 7 to define the characteristics and add stations 9 When done press BACK to return to the Ma...

Страница 7: ...Main Menu navigate to Scheduled Irrigation and press SELECT The Scheduled Irrigation menu displays 2 Navigate to and select Stations The Stations screen displays Figure 8 The pane on the left display...

Страница 8: ...he screen and to change values setting the following values POC used for Either Irrigation Non Irrigation or Not Used If there is no flow meter or master valve connected to this POC select Not Used Fl...

Страница 9: ...Station to activate the selected station The valve turns on and the Irrigation Details screen displays to show the progress Sharing Real Time Weather If the controller does not have an ET Gage and Ra...

Страница 10: ...n the CS3000 Sites heading tap or click Add CS3000 7 Type the Site ID and Serial Number noted in Step 3 and tap or click Add Site The controller is added 8 Tap or click Settings Weather Sharing The We...

Отзывы: