EMBER REMOTE CONTROL
The EMBER protocol is a
sophisticated data exchange
mechanism that has potential for
controlling many functions across
varied equipment types.
EMBER control has been incorporated
into Calrec’s Apollo, Artemis and Hydra2
range to allow remote control functionality
both over consoles and the wider Hydra2
network.
Currently, Calrec support the use of the
following EMBER controllers:
• L-S-B VSM
• Colledia BNCS
Please refer to the relevant
manufacturer’s guidance for specific
information relating to their products.
Currently, EMBER has the ability to control
the following features when connected to
a Calrec Apollo/Artemis/Hydra2 network:
• Loading of shows and user memories
onto control surfaces.
• Loading / removing alias files used
by consoles, instructing them to use
different pre-defined sets of I/O ports.
(Please refer to the console operator
manual for more information on the use
of alias files.)
• EMBER controllers can view and edit
the H20 based Hydra2 I/O box and
port labels.
• Inserting SMPTE2020 metadata
into Hydra2 SDI embedder outputs -
Metadata sets can be uploaded and
edited using the H20 application.
EMBER controllers can select any
of the available metadata sets for
insertion to, or removal from any of the
SDI embedder outputs on the network.
• EMBER controllers can selectively
mute any of the audio channels within
the SDI output of Hydra2 embedders.
Connection
The 3rd party EMBER client should
be connected to the single front panel
RJ45 labelled “Ethernet” on the main
(not expansion) router card. A backup
secondary connection can be made to
the secondary main router card. Systems
using both EMBER and SW-P-08 control
require the use of an external Ethernet
switch to allow both control systems to
connect to the same Ethernet port. The
two control systems are separated by
using different TCP socket port settings.
On Hydra2 networks with more than one
processing rack, the EMBER connections
should be made to the router cards in
the processing rack configured as the
Master Router. Slaved processing racks
do not support EMBER connections.
Connections made to the Master Router
can be given access to any console and
I/O on the network, irrespective of which
processing rack they are connected to.
The Router card Ethernet ports are
gigabit connections, which use standard
Ethernet straight-through or cross-over
pin-outs and pairings. Screened Cat5e
cable should be used to guarantee
performance.
The default IP address of the Ethernet
ports are the same as that of the router
cards themselves—xxx.yyy.5.0 for the
primary and xxx.yyy.6.0 for the secondary.
xxx.yyy is different for each processing
rack and can be checked using the Calrec
Program Updater application on the PC
associated with the rack in question.
The user must be logged into Windows
as
CalrecAdmin
with the password
calrec
in order to run the Calrec Program
Updater, which can be found in the Calrec
folder in the Windows Start menu. Upon
launch, the application checks for the
presence of local hardware and reports
back with IP addresses. All hardware
associated with the same processing
rack has the same first two bytes of IP
address. The router cards themselves can
be identified in the list by their unit number
being prefixed with “RY”. IP addresses for
the SW-P-08 connections can be aliased
if required to make them more suitable for
use with the 3rd party network, however
this must be carried out by a Calrec
Engineer and so should be discussed prior
to commissioning.
As well as addressing the routers by
IP, the EMBER controller needs to be
configured to use the TCP socket port of
61000.
Содержание Hydra2
Страница 1: ...calrec com Putting Sound in the Picture HYDRA2 INSTALLATION MANUAL Gigabit Ethernet Networking...
Страница 5: ...calrec com Putting Sound in the Picture HYDRA2 INFORMATION...
Страница 9: ...calrec com Putting Sound in the Picture HYDRA2 ARCHITECTURE NETWORKING...
Страница 28: ...28 HYDRA2 Installation Manual...
Страница 29: ...calrec com Putting Sound in the Picture HYDRA2 CONNECTION INFORMATION...
Страница 39: ...calrec com Putting Sound in the Picture HYDRA2 3RD PARTY REMOTE CONTROL...
Страница 42: ...42 HYDRA2 Installation Manual...
Страница 43: ...calrec com Putting Sound in the Picture HYDRA2 FIXED FORMAT I O...
Страница 70: ...70 HYDRA2 Installation Manual...
Страница 71: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O...
Страница 78: ...78 HYDRA2 Installation Manual...
Страница 79: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O CARDS...
Страница 97: ...calrec com Putting Sound in the Picture HYDRA2 OBSOLETE MODULAR I O CARDS...
Страница 99: ...calrec com Putting Sound in the Picture HYDRA2 SPECIFICATION...