96 HYDRA2
Installation Manual
Modular I/O Cards
WY5859 – GPIO, 8 IN / 16 OUT
GPIO cards can be fitted to provide
General Purpose interfacing for
logic control such as remote / fader
starts for playback devices, triggering
autofades on a control surface, and
much more.
This is a one slot wide module. Inputs
and outputs are all on 1 x female 50 pin
D-type connector.
Access to each general purpose input and
output can be given to any console on the
Hydra2 network.
The function of each general purpose
input and output is configurable and
assignable via Apollo/Artemis/Summa
console’s which have been granted
access.
LEDs
The Status LED strobes to indicate that
the local software is running. The LED
illuminates solidly when connection is
established to the Hydra2 Interface
Module in the same modular I/O chassis.
GPInputs
8 opto-isolated inputs allow for remote
control of console functions. Applying
between 3 and 50 Volts, AC or DC across
the + & - pins of the opto will trigger them.
If using a dry closure to trigger a GP input,
note that the incoming closure should be
wired to one side of an opto input only.
The other side of the opto should be
pulled up by linking it to the 5V pin on the
connector. The other side of the closure
should be wired to the 0V pin. An example
of wiring a closure to GP input #1 is
shown in Figure 2 on the previous page.
GPOutputs
The WY5859 version provides 16
normally open contact closure pairs. If
external equipment requires a ground for
activation, rather than a closure, one side
of the relay should be connected to a
ground from the external equipment and
the other side of the relay used as the
trigger.
FRONT PANEL VIEW
Function
Pin
GPI 1
+
1
-
34
GPI 2
+
18
-
2
GPI 3
+
35
-
19
GPI 4
+
3
-
36
GPI 5
+
20
-
4
GPI 6
+
37
-
21
GPI 7
+
5
-
38
GPI 8
+
22
-
6
Supply
+5 V
17
Supply
0 V
50
50 Pin Male D-Type - Wiring side of connecting cable
50
34
18
33
17
1
Function
Pin
GPO 1
GPO 2
GPO 3
GPO 4
GPO 5
GPO 6
GPO 7
GPO 8
GPO 9
GPO 10
GPO 11
GPO 12
GPO 14
GPO 15
GPO 16
GPO 13
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO -
NO +
NO -
NO +
NO -
NO +
NO -
NO -
NO +
NO -
NO +
NO -
NO +
NO +
39
23
7
40
24
8
41
25
9
42
26
10
43
27
11
44
28
12
45
29
13
46
30
14
47
31
15
48
32
16
49
33
GP INPUT PINS
GP OUTPUT PINS
See “Capacity” on page 18 for
information on Modular I/O box
capacity.
Содержание Hydra2
Страница 1: ...calrec com Putting Sound in the Picture HYDRA2 INSTALLATION MANUAL Gigabit Ethernet Networking...
Страница 5: ...calrec com Putting Sound in the Picture HYDRA2 INFORMATION...
Страница 9: ...calrec com Putting Sound in the Picture HYDRA2 ARCHITECTURE NETWORKING...
Страница 28: ...28 HYDRA2 Installation Manual...
Страница 29: ...calrec com Putting Sound in the Picture HYDRA2 CONNECTION INFORMATION...
Страница 39: ...calrec com Putting Sound in the Picture HYDRA2 3RD PARTY REMOTE CONTROL...
Страница 42: ...42 HYDRA2 Installation Manual...
Страница 43: ...calrec com Putting Sound in the Picture HYDRA2 FIXED FORMAT I O...
Страница 70: ...70 HYDRA2 Installation Manual...
Страница 71: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O...
Страница 78: ...78 HYDRA2 Installation Manual...
Страница 79: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O CARDS...
Страница 97: ...calrec com Putting Sound in the Picture HYDRA2 OBSOLETE MODULAR I O CARDS...
Страница 99: ...calrec com Putting Sound in the Picture HYDRA2 SPECIFICATION...