9
This range arrives from factory adjusted for use with
natural gas. If using LP/Propane gas is desired, range
must be converted. See “Type 1” or “Type 2” regulator.
Converting Type 1 Pressure Regulator for Use with
LP/Propane
1.
Remove pressure regulator cap with a wrench.
2.
Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3.
Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Cap must show “LPG10” or “LP10”.
A
B
C
A—Cap
B—Plastic Insert (LP setting)
C—Spring Location
Type 1 Pressure Regulator
4.
Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1.
Remove pressure regulator cap with a
wrench.
2.
Reverse pressure regulator cap.
• Cap must show “LP”.
3.
Place pressure regulator cap on pressure regulator
and tighten.
Cap
LP
Type 2 Pressure Regulator
WARNING
!
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Converting for Use With LP/Propane Gas