Page 8
FIG.3 CONSOLE LABEL/ MARKING
CONDENSATE
DISCHARGE FAULT
(RED).
MAINS LIGHT
(GREEN)
COOLING LIGHT
(AMBER)
DEFROST
LIGHT (WHITE)
DIGITAL
THERMOSTAT
FAULT LAMPS
HIGH PRESSURE LOW PRESSURE
(RED)
(RED)
HIGH
PRESSURE
RE-SET
LOW PRESSURE
RE-SET
FAN ONLY
POSITION
COOLING
POSITION
OFF POSITION
FAN SPEED LOW
FAN SPEED
SWITCH
FAN SPEED
HIGH
7) OPERATING INSTRUCTIONS.
The Control Panel on the room unit is
illustrated below,
AIR CONDITIONER PAC6500AX
a) Plug in the room unit mains cable, and
switch on electricity, red mains light will
illuminate.
b) Select "Fan Only" with the mode
switch. The fan will start.
c) Select "Fan Speed", with the fan speed
switch, high or low depending on air
velocity required.
d) Select "Cooling" with the mode switch.
e) The PAC6500 is fitted with a digital
thermostat which is factory preset at 28ºC.
With the PAC set like this the PAC starts to
cool at 29ºC and will stop cooling at 28ºC.
The thermostat is marked TLZ11
Changing the set point.
Thermostat marked TLZ11
Press P button once and release. Set Point
and set point value (28) will be displayed
alternately.
Press the
or
key to change the value
of the set point. Once the desired value is
displayed press P again to memorise the
value.