HEATER ON/OFF:

To start the heater press this button and it’s green light will come on.  To disable the
heater press this button and its green light will go off.

THERMOSTAT BUTTONS:

Pressing the + button will raise the set temperature.  Pressing the - button will lower the
set temperature.  When either button is pressed the LED display will begin to flash.  The
flashing numbers indicate the thermostat setting.

MODE SELECT BUTTONS-POOL or SPA:  

The heater has two thermostat modes for

two different desired temperature settings, one for pool mode and one for spa mode.
If you do not have a spa use the pool mode only. If you do have a spa, you can connect
two Jandy™ motorized plumbing valves.  Therefore, when you select either mode the
motorized valves will turn to isolate the heater to either the pool or spa.  NOTE: There
is a 30 second delay when switching pool/spa modes.

OPTIONAL” WATER PUMP TIME CLOCK OVERRIDE OPERATION  

When the T.C.O. but-

ton is set to the ON mode, the Time Clock Override feature is designed to start the
water pump whenever the pool requires heat.  Once the pool is up to the set tempera-
ture the heater will stop and then 5 minutes later the water pump will stop. When this
button is set to the OFF mode, the heater will operate only when the water pump is
running during the timed period set on the water pumps time clock.
NOTE: The time clock override works best if used during cooler weather conditions
where the pool is losing more than 8 to 10 degrees over night or when the pool is
being heated from “dead cold”.
NOTE: If the time clock override starts the water pump and the thermostat does not
continue to call for heat for at least 5 minutes, the control will shut the water pump and
heater off. Thereafter, it will not re-attempt to start the water pump for 4 hours.  This 4
hour delay can be bypassed by pressing the T.C.O. button off then back on.
NOTE:  When the T.C.O. button is activated while in “spa mode” the water pump will
run the entire time you are in  spa mode. When you switch back to pool mode there
will be a 5 minute delay before the water pump shuts off.  The T.C.O. option is built
into the heater at the factory and can not be added later.

Page 4

“Digital Logic” Digital Control Panel Information

Содержание Aquatherm DIGITAL LOGIC AT1000

Страница 1: ...nge without notice NATIONAL POOL SPA INSTITUTE SWIMMING POOL SPA HEAT PUMPS NOTE Installers should see separate installation manual Model AT1000 AT800 AT600 AT400 BLACK CABINET with DIGITAL CONTROLS O...

Страница 2: ...lations on the purchase of your new swimming pool spa heat pump Utilizing heat pump technology is the most efficent method of heating a swimming pool Please take a few minutes to read this owner s man...

Страница 3: ...The liquid refrigerant in the air coil absorbs the available heat in the ambient air transforming it into a gas The refrigerant gas is then pumped into the compressor When this warmed gas is com pres...

Страница 4: ...the water pump whenever the pool requires heat Once the pool is up to the set tempera ture the heater will stop and then 5 minutes later the water pump will stop When this button is set to the OFF mo...

Страница 5: ...e water pump is off DF DEFROST MODE This readout indicates that the internal defrost safety control has disabled the heater During cold weather where the air temperature drops below approximately 45 t...

Страница 6: ...D display will show a constant readout of the actual cur rent water temperature To set the desired water temperature press either the or thermostat buttons While adjusting the set temperature the LED...

Страница 7: ...educe heat loss by as much as 80 and reduce heating costs as much as 50 Using a cover during the initial heat up period will greatly reduce the operational time needed 8 SPA HEATING When heating a spa...

Страница 8: ...er is not restricted Make sure the unit can breathe well The cooler discharge air from the top should not accumulate and be drawn into the side air intake coils Keep all plants and shrubs trimmed away...

Страница 9: ...IN THE POOL or SPA SKIMMER Chemicals placed in the skimmer will feed concentrated chemicals or chlorine into the heat exchanger before it is diluted with the rest of the pool water Chemicals or chlo r...

Страница 10: ...p A minimal air coil cleaning should be done as needed and at least two times per year If the heater is installed in a sandy or salty condition the air coil should be cleaned more frequently 3 To clea...

Страница 11: ...ns T Stat Relay Does Not Close Heater Does Not Activate After Delay Period Try Again or Possible Bad Time Delay Possible Bad T Stat Board Pot or Sensor 1 Hour Time Delay Activates Water Temperature is...

Страница 12: ...or improper water balance Sprinkler damage Roof run off damage Freeze damage or operation damage during freezing conditions Salt and or sand debris damage Lack of maintenance and or cleaning Unauthor...

Отзывы: