1.  Make sure the unit has a firm base. The heat pump will produce condensation
(water) while in operation. You will notice water coming from the bottom drain ports
when the unit is running.  The condensation will increase as the outdoor air humidity
level increases.

Make sure the bottom drain ports do not become clogged with debris.  Make sure the
run off water does not puddle inside the heater and does not undermine the equip-
ment base.

2.  Keep the top air flow discharge & air flow intake area clear as shown here so the air
flow through the heater is not restricted.  Make sure the unit can “breathe” well. The
cooler discharge air from the top should not accumulate and be drawn into the side air
intake coils. Keep all plants and shrubs trimmed away from the heater.  Make sure the
front is accessible for future service.

3. Do not allow lawn sprinklers to spray on the heater in any way.   Keep sprinkler heads
away from the heat pump to prevent corrosion and damage.  Use a deflector if needed.

4.  If the unit is installed under a steep roof pitch or under a roof valley that has no
gutter, a gutter or diverter should be fitted to prevent excessive water from pouring
through the unit.

Air Flow & Access Clearances

Heat Pump Maintenance & Precautions

AIR COIL

(on 3 Sides)

Page 8

BASE

(CONCRETE OR PREFAB)

Содержание Aquatherm DIGITAL LOGIC AT1000

Страница 1: ...nge without notice NATIONAL POOL SPA INSTITUTE SWIMMING POOL SPA HEAT PUMPS NOTE Installers should see separate installation manual Model AT1000 AT800 AT600 AT400 BLACK CABINET with DIGITAL CONTROLS O...

Страница 2: ...lations on the purchase of your new swimming pool spa heat pump Utilizing heat pump technology is the most efficent method of heating a swimming pool Please take a few minutes to read this owner s man...

Страница 3: ...The liquid refrigerant in the air coil absorbs the available heat in the ambient air transforming it into a gas The refrigerant gas is then pumped into the compressor When this warmed gas is com pres...

Страница 4: ...the water pump whenever the pool requires heat Once the pool is up to the set tempera ture the heater will stop and then 5 minutes later the water pump will stop When this button is set to the OFF mo...

Страница 5: ...e water pump is off DF DEFROST MODE This readout indicates that the internal defrost safety control has disabled the heater During cold weather where the air temperature drops below approximately 45 t...

Страница 6: ...D display will show a constant readout of the actual cur rent water temperature To set the desired water temperature press either the or thermostat buttons While adjusting the set temperature the LED...

Страница 7: ...educe heat loss by as much as 80 and reduce heating costs as much as 50 Using a cover during the initial heat up period will greatly reduce the operational time needed 8 SPA HEATING When heating a spa...

Страница 8: ...er is not restricted Make sure the unit can breathe well The cooler discharge air from the top should not accumulate and be drawn into the side air intake coils Keep all plants and shrubs trimmed away...

Страница 9: ...IN THE POOL or SPA SKIMMER Chemicals placed in the skimmer will feed concentrated chemicals or chlorine into the heat exchanger before it is diluted with the rest of the pool water Chemicals or chlo r...

Страница 10: ...p A minimal air coil cleaning should be done as needed and at least two times per year If the heater is installed in a sandy or salty condition the air coil should be cleaned more frequently 3 To clea...

Страница 11: ...ns T Stat Relay Does Not Close Heater Does Not Activate After Delay Period Try Again or Possible Bad Time Delay Possible Bad T Stat Board Pot or Sensor 1 Hour Time Delay Activates Water Temperature is...

Страница 12: ...or improper water balance Sprinkler damage Roof run off damage Freeze damage or operation damage during freezing conditions Salt and or sand debris damage Lack of maintenance and or cleaning Unauthor...

Отзывы: