Calomax have manufactured water boilers in the UK for over 50 

years. We are proud of our products and the back-up service we 

provide

Properly maintained and serviced, a Calomax boiler should last 

many  years  and  we  have  no  hesitation  in  providing  a  full  12 

months (mainland U.K.) parts and labour warranty for all models. 

Please complete and return the enclosed product registration form 

as soon as possible    to activate this, or register online at www.

calomax.co.uk .

In  addition,  the  Clipper,  Kudos  and  Quantum  models  carry  an 

additional 12 month back to base warranty. 

Some  factors  are  beyond  our  control  and  would  invalidate  the 

warranty offered. These include:

 

Incorrect installation

 

High / Low water pressure

 

Incorrect voltage supply

 

Accidental damage

 

Limescale build-up

The  last  item  can  be  a  particular  problem  for  water  dispensing 

equipment in hard-water areas. All hot water equipment should be 

serviced and de-scaled by approved organisations on a regular 

basis to avoid a damaging build-up of limescale.

Although  our  boilers  incorporate  scale-inhibitor  technology,  we 

recommend  that  a  taste,  odour  and  scale  filter  should  be  fitted 

where appropriate.

Please  visit  our  website  www.calomax.co.uk  for  details  of  our 

Service Partner Network and the range of filters and accessories 

available

WARRANTY GUARANTEE (UK Mainland customers only)

Содержание QUANTUM-e

Страница 1: ...Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before operating your boiler for the first time Issue 4 09 07 13 DCR 872 MODEL QUANTUM e Incorporating On Off switch ...

Страница 2: ...EIGHTS 5 VENT OVERFLOW 6 ELECTRICAL CONNECTIONS 6 USER INSTRUCTIONS 6 SCALE 7 GENERAL OPERATION 8 GENERAL NOTES 8 CLEANING 8 ACCESSORIES 9 10 SERVICE INSTRUCTIONS 11 14 15 EXPLODED DIAGRAM 12 13 SPARE PARTS 16 17 WIRING DIAGRAM 18 TROUBLE SHOOTING 19 MAINTENANCE AND SERVICE HISTORY 20 21 22 WARRANTY 23 PRODUCT SPECIFICATION 24 PAGE ...

Страница 3: ...rts have been supplied with the boiler 1 WRAS approved flexible water inlet hose suitable for potable water 2 2 keys for keyswitch mechanism 3 BPDTK plastic stainless free standing drip tray This product conforms to the CE marking directive 93 68 EEC through compliance with the following standards Electromagnetic Compatibility Directive Low Voltage Directive 73 23 EEC in accordance with BS EN 6033...

Страница 4: ...he boiler on a surface suitable for near boiling temperatures and the working weight of the boiler Allow adequate clearance for ventiation and for the easy removal of the outer casing lid and rear panel Calomax ltd recommend a minimum clearance of 50mm on all sides of the boiler A suitably qualified engineer must install this unit Plumbing and electrical installation work is involved INSTALLATION ...

Страница 5: ...complies with UK water regulations The hose should be connected to a 15mm drinking water supply via an appropriate isolating valve The supply must provide a constant pressure of between 20 KPa and 1000 KPa 0 2 to 10 Bar If the water supply contains excessive solids in suspension it is recommended that a fine mesh in line water filter is fitted in the pipe work after the stop cock Failures due to s...

Страница 6: ...ment covered the element will be energised as well as the solenoid When the selected operating level is reached the solenoid will turn off and the element will remain on until full operating temperature is reached With the key switch in the ON position the push button will stop flashing and show solid colour when the boiler is up to full temperature and the button will be enabled at this point the...

Страница 7: ...ched off and on again Re setting commission mode In normal use the boiler will always be at operating temperature indicated by the Ready light showing a solid not flashing colour When the boiler is full and ready the Full light will also be illuminated When the key switch is turned on the dispense button will illuminate with solid colour to indicate water is available e Energy saving system When t...

Страница 8: ...and potential damage to the appliance Misuse of such chemicals is not covered by the product warranty The Quantum e boiler benefits from an integral scale inhibitor this is not a scale eliminator and its effects will differ according to the water quality in your area To ensure trouble free operation periodically check for scale inside the boiling chamber The production of scale is a natural phenom...

Страница 9: ... Worktop mounting Stainless Steel drip tray Ref HSSDTK freestanding Boiler securing clamp To fix boiler to a worktop Ref QEC Ingredient caddy Ref IC3 3 bay as shown Shelf unit Ref SHU IC4 4 bay HSSDTWDK with drain outlet ...

Страница 10: ... For more information visit our website at www calomax co uk or call 0113 249 6681 Fused spur time switch Ref 7DFST Max 3kW Water filter kit To reduce taste odour problems Ref CWFK Filter Cartridge Replacement filter for kit shown above Ref CWFC1 ...

Страница 11: ...le the service indicator is flashing a 4x pulse For further assistance contact our service department on 0113 249 6681 e mail service calomax co uk or find a local service engineer at www calomax co uk Note When the green service indicator light on the front of the boiler is showing solid colour the machine has been starved of water for in excess of 20 minutes and the solenoid valve has been disab...

Страница 12: ...Page 12 1 2 2 3 5 6 9 15 17 If parts required are not identifie please contact Calomax Limited E Body cut away to show internal components Outer Casing removed for clarity 13 18 ...

Страница 13: ...Page 13 7 8 9 10 11 12 14 16 identified x Limited Includes nuts washers etc Exploded parts view for Quantum e boiler To be read in conjunction with the spare parts list how ed 19 20 ...

Страница 14: ... manufacturers recommendations This will prevent health and safety issues taste problems and potential damage to the appliance All trace of these chemicals must be removed from the appliance before re commissioning the unit Misuse of such chemicals is not covered by the product warranty IMPORTANT Before re commissioning the boiler it is important that all scale and moisture is removed from the lev...

Страница 15: ...B In the event of a PCB failing and a replacement being required full instructions will be supplied It is important to note however that the Triac PCB must be securely mounted against the copper heat sink to ensure reliable heat dissipation Heat transfer compound is also supplied with all replacement circuit boards Adjusting the Water Temperature Set Point The temperature potentiometer Pot is pre ...

Страница 16: ...SE VALVE SERVICE KIT KEYSWITCH INCLUDES 2 KEYS ECO PUSH BUTTON Inc FITTING TOOL MAIN PRINTED CIRCUIT BOARD Inc TRIAC WATER DISPENSE PUSH BUTTON Inc FITTING TOOL AUXILIARY PCB ELEMENT 3kW THERMISTOR ASSEMBLY KIT SOLENOID VALVE BODY LID GASKET WATER INLET HOSE MANUAL RESET THERMAL CUTOUT LEVEL PROBES KIT BODY LID GROMMET 1 2 3 4 8 7 6 5 9 10 11 12 16 15 14 13 DVSK QKK SPARE KEYS x2 FOR QKM X1 ...

Страница 17: ...e usually available ex stock Please quote Model Serial Number NB Not to scale QUFK UPPER FASCIA KIT 17 LOWER FASCIA KIT 18 SERVICE VALVE KIT 19 QELFK SVK SINGLE POLE ON OFF SWITCH 20 SPRSK 21 FIH 1m IH2M 2m WATER INLET HOSE ...

Страница 18: ...LUG COLD WATER INLET SOLENOID VALVE ELEMENT TRIAC PCB HIGH NORMAL LOW LEVEL SENSORS HOT WATER OUTLET DISPENSE VALVE HEATER LED SOLENOID LED THERMISTOR THERMAL CUTOUT EARTH ON BODY EARTH ON BASE GREEN WHITE OPT2 U1 OP1 EARTH ON CASING OPT1 ENERGY SAVING BROWN BLUE BROWN ORANGE ORANGE YELLOW RED BLUE LOWER YELLOW PUSH BUTTON ON FRONT PANEL KEYSWITCH ON FRONT PANEL PINK PINK ORANGE YELLOW RED BLUE UP...

Страница 19: ... 12 Faulty wiring to thermistors faulty thermistors Temperature controller needs adjusting Element failed to earth Defective Printed Circuit Board De scale the boiler Particularly thermistor Repair replace as required Lower operating temperature Replace element Replace Circuit Board Overflows Dirt in solenoid valve Level sensors require de scaling or replacing Printed circuit board faulty Clean so...

Страница 20: ...Page 20 MAINTENANCE AND SERVICE HISTORY ...

Страница 21: ...Page 21 MAINTENANCE AND SERVICE HISTORY ...

Страница 22: ...Page 22 MAINTENANCE AND SERVICE HISTORY ...

Страница 23: ...y Some factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Limescale build up The last item can be a particular problem for water dispensing equipment in hard water areas All hot water equipment should be serviced and de scaled by approved organisations on a regular basis to...

Страница 24: ...Average flow rate from dispense valve 2 8 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER SERIAL NUMBER FOR FUTURE REFERENCE Note All measurements are approximate PLEASECONTACTOURSERVICEDEPARTMENTFORASSISTANCE Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk ...