ALKON  

09

R 18 - C 18
R 24 - C 24

USER’S OPERATING

INSTRUCTIONS

Содержание Alkon 09 R 18

Страница 1: ...00333177 1st edition 06 2009 ALKON 09 R 18 C 18 R 24 C 24 USER SOPERATING INSTRUCTIONS ...

Страница 2: ...or it is essential to carefully follow the instructions indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water areas where the main water can exceed 15 f total hardness a scale reducing device is recom mended The choice of this device has to be made taking into consideration the water s charac...

Страница 3: ...e held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must be carried out by a competent person and installed in accordance with the current standards and regulations Failure to correctly install this applian ce could cause injury to persons animals or damage...

Страница 4: ...ng water temperature which can be adjusted between a minimum of 30 C and a maximum of 85 C D H W temperature controller In the ALKON R models this function is active only if the boiler is connected to an external D H W storage tank Through this knob it is possible to adjust the temperature of the D H W NOTE In the ALKON R models not connected to an external D H W storage tank the pointer of the kn...

Страница 5: ...s shown flashing on the display Reset button By pressing this push button it is possible To restart the boiler after a lockout due to the burner control which has lit on the display the symbol To have the error code shown on the display if the boiler operation was not stopped by this fault To activate the special function for calibration To enter the Service Menu and select the parameters Indicati...

Страница 6: ...mostat position the pointer of the knob B in an intermediate position During the operation in C H mode on the display the actual boiler water temperature and the symbol are shown Put out of operation In order to put completely out of operation the boiler cut the power supply to the boiler through the external main switch In case of long periods of inactive state of the boiler close also the gas an...

Страница 7: ...r Sales Service Centre C Error code Meaning Too low water pressure in the C H circuit Elimination of the fault Restore the correct pressure value by regulating the boiler s filling valve for correct boiler operation the pressure should be between 0 8 and 1 bar When the correct pressure value has been reached the led will switch off automatically and normal boiler operation will be restored DANGER ...

Страница 8: ...al ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...