background image

Page 2

CONTENTS

INTRODUCTION    

 

 

       

             3

CHECK LIST 

 

 

 

 

             3

APPROVALS 

 

 

 

                          3

CONSTRUCTION  

 

 

                          4

INSTALLATION

 

 

 

 

 

 

4

LOCATION  

 

 

 

 

 

4

COLD WATER INLET 

 

 

 

 

5

ACCESS INSTRUCTIONS   

 

 

 

6

VENT / OVERFLOW 

 

 

 

 

7

ELECTRICAL CONNECTIONS 

 

 

 

8

USER INSTRUCTIONS

 

 

 

 

 

8

SCALE  

 

 

 

 

 

9

GENERAL OPERATION  

 

 

 

9

CLEANING  

 

 

 

 

 

9

TROUBLE SHOOTING 

 

 

 

 

10

ACCESSORIES  

 

 

 

 

11

SPARE PARTS  

 

 

 

 

12/13

EXPLODED DIAGRAM

 

 

 

 

 

14

/

15/16/17

SERVICE INSTRUCTIONS   

 

 

 

18/19

GENERAL FUNCTION  

 

 

 

20

WIRING DIAGRAM  

 

 

 

 

21

DIMENSIONS AND WEIGHTS  

 

 

22

WARRANTY 

 

 

 

 

 

23 

PRODUCT SPECIFICATION 

 

 

 

24 

PAGE

Содержание Eclipse Series

Страница 1: ...RANGE OF WATER BOILERS Please read these instructions carefully before operating your boiler for the first time Issue 5 06 11 2015 DCR 939 Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681...

Страница 2: ...TRUCTIONS 6 VENT OVERFLOW 7 ELECTRICAL CONNECTIONS 8 USER INSTRUCTIONS 8 SCALE 9 GENERAL OPERATION 9 CLEANING 9 TROUBLE SHOOTING 10 ACCESSORIES 11 SPARE PARTS 12 13 EXPLODED DIAGRAM 14 15 16 17 SERVIC...

Страница 3: ...ing parts have been supplied with the boiler 1 Wall mounting bracket This product conforms to the CE marking directive 93 68 EEC through compliance with the following standards Electromagnetic Compati...

Страница 4: ...d to operators that are suitably trained or where untrained operators of the machine can be supervised by trained personnel Calomax products have been tested and found to comply with the requirements...

Страница 5: ...odels only Do not reuse old hoses The supply must provide a constant pressure of between 20 KPa and 1000 KPa 0 2 to 10 Bar If the water supply contains excessive solids in suspension it is recommended...

Страница 6: ...ont panel Prise off the outercasing lid from its mounting clips remove the top two panel mounting screws and the third bottom mounting screw where fitted Remove the cover The 3C5C model does not have...

Страница 7: ...ischarge into the drip tray and then plumbing the drip tray to a safe and visible point of discharge If the machine is operated without the overfill pipe being extended as advised any subsequent damag...

Страница 8: ...e solenoid will continue to fill the boiler to the normal operating water level When the water has reached the normal operating temperature the Wait light will extinguish and the ready light will illu...

Страница 9: ...to the water quality in your area To ensure trouble free operation periodically check for scale inside the boiling chamber De scaling may be required within the first 12 months This is not covered und...

Страница 10: ...ted Circuit Board De scale the boiler Particularly thermistor Repair replace as required Lower operating temperature Replace element Replace Circuit Board Overflows Dirt in solenoid valve Level sensor...

Страница 11: ...ug in time switch Ref 7DPIT Max 3 kW Water filter kit To reduce taste odour problems Ref CWFK Filter Cartridge Replacement filter for kit shown above Ref CWFC1 For more information visit our website a...

Страница 12: ...UP WASHER TAP SPRING DRAW OFF TAP BODY TAP SLOTTED STEM DRAW OFF TAP BODY ECLIPSE HEAT SHIELD SLOW FILL NOZZLE ECLIPSE P C B TESTED ECLIPSE LIGHT PCB TESTED ELEMENT 3kW RESET KIT ECLIPSE THERMISTOR AS...

Страница 13: ...e ex stock Please quote Model Serial Number 17 ELPK PS ESSK ECLIPSE LEVEL PROBES KIT ECLIPSE SILICONE SEAL KIT POWER SWITCH 18 19 20 NBPRG BODY LID GROMMET X8 various sizes 21 FIH 1m IH2M 2m WATER INL...

Страница 14: ...Page 14 11 12 19 Complete set of 8 seals 2 sizes Exploded parts view for Eclipse wall mounted boilers To be read in conjunction with the spare parts list 15 15 16 or 17...

Страница 15: ...Page 15 1 2 4 3 7 8 5 13 20 18 If parts required are not identified please contact Calomax Limited behind cap 9 10 inside moulding...

Страница 16: ...Page 16 Exploded parts view for Eclipse Counter Top Models To be read in conjunction with the spare parts list 11 12 19 15 or 14 17 Complete set of 8 seals 2 sizes...

Страница 17: ...Page 17 1 If parts required are not identified please contact Calomax Limited 2 4 3 6 20 9 13 22 10 18 inside moulding behind cap...

Страница 18: ...r filled due to debris trapped in the solenoid valve The debris can be removed by drawing plenty of water from the dispense tap causing the solenoid valve to operate and flush out the obstruction The...

Страница 19: ...scalants must only be used in accordance with the manufacturer s recommendations This will prevent health and safety issues taste problems and potential damage to the appliance All trace of these che...

Страница 20: ...l is switched Printed Circuit Board replacement PCB In the unlikely event of a PCB failing and a replacement being required full instructions will be supplied It is important to note however that the...

Страница 21: ...ET SOLENOID VALVE POWER SWITCH THERMISTOR EARTH ON WATER TANK EARTH ON WRAPPER ELEMENT WITH THERMAL CUTOUT NC LIGHT CIRCUIT BOARD LOW ECO NORMAL HIGH LEVEL SENSORS GREY 0 75mm GREY 0 75mm BLACK 1 5mm...

Страница 22: ...m 443 570 Depth mm 355 355 Width mm 240 240 Drip tray clearance mm 150 175 Working weight Kg 20 30 5 MODEL 2W3 3W5 3W7 5 3W10 3W15C Height mm 435 510 610 610 610 Depth mm 270 270 270 270 270 Width mm...

Страница 23: ...e factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Limescale build up Th...

Страница 24: ...Serial Number Draw off Capacity 3C5 3C5C 3C10 2W3 3W5 3W7 5 3W10 3W15 5 Litres 5 Litres 10 Litres 3 Litres 5 Litres 7 5 Litres 10 Litres 15 Litres Heat up Time First fill to full capacity 3C5C 3C10 2W...

Отзывы: