This equipment is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the
appliance
In the event of the power supply lead to the boiler becoming damaged,
the appliance must be removed from service. A replacement genuine part
is available from Calomax Ltd, and must be fitted by a suitably qualified
engineer
Commissioning
Turn on the water supply and then switch on the electrical supply.
When the power switch is pressed on the front fascia the Wait light
will illuminate and the unit will fill with water (1.3 L/Min). When water
reaches the low water level sensor, the element will be energised and
the solenoid will continue to fill the boiler to the normal operating water
level. When the water has reached the normal operating temperature,
the Wait light will extinguish and the ready light will illuminate. At this
time the full light will be illuminated indicating that the machine has
reached full capacity of boiling water.
Subsequent Use
After the boiler has finished the commissioning cycle, and water is
drawn from the tap, water will be replenished in short cycles (Small
amount of water and then heat). The solenoid and element will never
be on at the same time unless the boiler is switched off and on again
(Re-setting commission mode). In normal use the boiler will always be
USER INSTRUCTIONS
During normal operation some external parts will become
very hot, particularly the tap body. Care must be taken to
avoid injury, a burn or scald.
ELECTRICAL CONNECTIONS
The boiler should be connected to a 240v ac 13A electrical supply,
capable of carrying a load of 3kW. The installation of a residual current
device (RCD) having a rated residual operating current not exceeding
30 mA is advisable.