background image

CALIFORNIA ACCENT LIGHTING, INC.

2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

5 / 20 / 2021 / Rev 3

Page 7 of 20

ALS

500T-SWM-MI

INSTALLATION INSTRUCTIONS

Mounting (Aircraft Cable Assembly) 1 of 3

Ceiling Line

Mounting Surface

~7”

Aircraft Cable

Cable Gripper

Excess cable

Aircraft Cable

Cable Gripper

Hex Nut

Flat Bracket

Hex Nut

Hex Head Bolt

Projected Location of

Hard Ceiling Drywall

Ceiling Line

5/8” Drywall

Wall Stud

6-1/4”

Ceiling Line

Mount Wall Trim

Ceiling Line

4”

Determine number of Aircraft Cable Assemblies required.

Note:

 Refer to the diagrams on page 14 as a guide.     

4

Hang or cut drywall along installation area so it is exactly 4” above ceiling line. 

Note:

 Drywallers must hang drywall to the specifications. Only cut if necessary.

2

Mark locations along Wall Trim extrusion where it will be mounted to wall studs, 
then drill holes as needed and mount to wall studs. 

Note:

 Mount Wall Trim extrusion using at least 1 screw per 2’, rounded up.

3

If applicable, assemble Aircraft Cable Assemblies. Install hex nuts about halfway 
down each hex head bolt, then insert bolts through flat bracket and secure with 
hex nuts.

5

Determine locations where Aircraft Cables will be mounted overhead. Secure to a 
sturdy surface, such as studs, using hardware (by others) that is rated for the
weight of the luminaire.

Note:

 Do not hang luminaire from weak material such as drywall or plywood.

6

Secure Aircraft Cable Assemblies to mounting surface. The top of the assembly 
should rest approximately 7” above ceiling line. Adjust position of assembly along 
aircraft cable using cable gripper. Do not trim excess cable at this time.

7

Install concealed ceiling system grid. Assemble the grid so there is a continuous 
6-1/4” opening where luminaires will be installed. The installation area must 
have at least 10” of overhead space from ceiling line.

Note:

 Do not hang ceiling drywall before luminaires are installed. Luminaires 

must be mounted prior to installation of ceiling drywall to allow top access.

1

Содержание ALS500T-SWM-MI

Страница 1: ...are Ensure surface material can support the weight of the luminaire ELECTRICAL INSTALLATION RECOMMENDATIONS INSTALLATION TOOL REQUIRED ALS500T SWM requires a remote driver The driver may be mounted on...

Страница 2: ...urce To Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last segment of...

Страница 3: ...prior notice 5 20 2021 Rev 3 Page 3 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Hanging Bracket Assembly Hard Ceiling Reflective Film 5 8 Drywall Wall Stud Wall Trim Lens Trim...

Страница 4: ...essary Note Use 8 32 x 2 Countersink Screw By others 6 Install Hanging Bracket Arms to luminaire by sliding inverted Hex Head Bolts of Hanging Bracket into the channels pictured below Do not slide int...

Страница 5: ...piece of drywall to perfect the height at which the luminaires will rest The drywall will be tucked into the gap between the Hard Ceiling Trim and the concealed ceiling grid when hung Note One person...

Страница 6: ...es or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 6 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Assembly Hard Ceiling 5 8 Drywall 1 8 Mud Wa...

Страница 7: ...ounted to wall studs then drill holes as needed and mount to wall studs Note Mount Wall Trim extrusion using at least 1 screw per 2 rounded up 3 If applicable assemble Aircraft Cable Assemblies Instal...

Страница 8: ...ll corners first 9 If applicable install end cap to end of run 10 After all luminaires have been mounted secure Aircraft Cable Assemblies to luminaire by tightening lower hex nuts All aircraft cables...

Страница 9: ...lead wires from driver Verify wiring diagram before connecting 16 Perform a continuity test before connecting luminaire to power source Refer to page 19 for continuity test step by step 17 Verify dri...

Страница 10: ...make changes or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 10 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Mounting Bracket Assembly Hard Ceiling 5 8 Dryw...

Страница 11: ...Lock Washer and Hex Nut on bolts Leave the assembly loose for now 5 Hang luminaire from mounted Wall Trim and hold in place Have another person slide Mounting Brackets onto luminaire and Wall Trim Ti...

Страница 12: ...lds the luminaire and another person adjusts hex nuts 10 If applicable position the driver in the center of luminaire and secure using set screws by others Do not mount drivers between luminaires Note...

Страница 13: ...et Rail Bracket ALS500T SWM 6 8 Hanging Bracket Rail Bracket For luminaires 1 long use 1 Rail Bracket and 2 Hanging Brackets Install 2 Hanging Brackets 2 from each end of 1 Rail Bracket Align the 1 Ra...

Страница 14: ...1 5 Aircraft Cable Assembly 4 ALS500T SWM 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire N...

Страница 15: ...00T SWM 1 5 4 Mounting Bracket Wall Trim ALS500T SWM 6 8 4 Mounting Bracket Wall Trim For luminaires 1 5 long use 2 Mounting Brackets per luminaire Install each bracket about 4 from each end of lumina...

Страница 16: ...blade for cutting metal Note If applicable remove Connector Blocks from extrusion before cutting 1 Position luminaires together and align the screw of the Male Block to meet the Female Block Tighten...

Страница 17: ...n trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut a 2 se...

Страница 18: ...ormula 409 FEATURES MAINTENANCE SPECIFICATIONS REFLECTANCE 550NM 97 5 0 8 ASTM E1164 L VALUE 98 9 ASTM E308 A VALUE 0 35 0 25 ASTM E308 B VALUE 0 90 0 30 ASTM E308 GLOSS 60 5 0 ASTM D2456 THICKNESS 20...

Страница 19: ...ath is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify the malfunction in the line If there is no conductive path the multimeter w...

Страница 20: ...ctory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a ra...

Отзывы: