background image

CALIFORNIA ACCENT LIGHTING, INC.

2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

5 / 20 / 2021 / Rev 3

Page 4 of 20

ALS

500T-SWM-MI

INSTALLATION INSTRUCTIONS

Mounting (Hanging Bracket Assembly ) 1 of 2

Ceiling Line

Mount Wall Trim

Projected Location of

Hard Ceiling Drywall

Ceiling Line

5/8” Drywall

Wall Stud

6-1/4”

Ceiling Line

Mark Wall Stud

6”

4”

Countersink Screw

Rail Bracket

Hex Nut

8-32 x 3”

Hex Head Bolt

Lock Washer

Slot

Hanging Bracket Arm

Determine number of Hanging Brackets required.

Note:

 Refer to the diagrams on page 13 as a guide.     

4

If applicable, assemble Hanging Bracket Arms. Insert Hex Head Bolts through 
slots on Hanging Bracket Arms and secure with washers and hex nuts. 

5

Mark locations where each Rail Bracket will be installed along reference line. 
Align the bottom of the Rail Bracket with the reference line and pre-drill using 
proper drill bit for surface and screw size. Each rail must be mounted with a 
minimum of two screws. Drill additional holes in Rail Brackets if necessary. 

Note:

 Use 8/32 x 2” Countersink Screw (By others)

6

Install Hanging Bracket Arms to luminaire by sliding inverted Hex Head Bolts of 
Hanging Bracket into the channels pictured below.
Do not slide into any other channels.

Note:

 All Hex Head Bolts must be vertical after mounting luminaire. If bolts are 

crooked or slanted, the Hanging Bracket must be adjusted.

7

If applicable, install end caps to ends of runs.

8

Install concealed ceiling system grid. Assemble the grid so there is a continuous 
6-1/4” opening where luminaires will be installed. The installation area must 
have at least 10” of overhead space from ceiling line.

Note:

 Do not hang ceiling drywall before luminaires are installed. Luminaires 

must be mounted prior to installation of ceiling drywall to allow top access.

1

Hang or cut drywall along installation area so it is exactly 4” above ceiling line. 
Measure exactly 6” above ceiling line and mark each wall stud in the installation 
area. Use a laser level to ensure accurate relation to ceiling line, then draw a 
reference line connecting each mark along the wall studs.

Note:

 Drywallers must hang drywall to the specifications. Only cut if necessary.

2

Mark locations along Wall Trim extrusion where it will be mounted to wall studs, 
then drill holes as needed and mount to wall studs. 

Note:

 Mount Wall Trim extrusion using at least 1 screw per 2’, rounded up.

3

Содержание ALS500T-SWM-MI

Страница 1: ...are Ensure surface material can support the weight of the luminaire ELECTRICAL INSTALLATION RECOMMENDATIONS INSTALLATION TOOL REQUIRED ALS500T SWM requires a remote driver The driver may be mounted on...

Страница 2: ...urce To Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last segment of...

Страница 3: ...prior notice 5 20 2021 Rev 3 Page 3 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Hanging Bracket Assembly Hard Ceiling Reflective Film 5 8 Drywall Wall Stud Wall Trim Lens Trim...

Страница 4: ...essary Note Use 8 32 x 2 Countersink Screw By others 6 Install Hanging Bracket Arms to luminaire by sliding inverted Hex Head Bolts of Hanging Bracket into the channels pictured below Do not slide int...

Страница 5: ...piece of drywall to perfect the height at which the luminaires will rest The drywall will be tucked into the gap between the Hard Ceiling Trim and the concealed ceiling grid when hung Note One person...

Страница 6: ...es or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 6 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Assembly Hard Ceiling 5 8 Drywall 1 8 Mud Wa...

Страница 7: ...ounted to wall studs then drill holes as needed and mount to wall studs Note Mount Wall Trim extrusion using at least 1 screw per 2 rounded up 3 If applicable assemble Aircraft Cable Assemblies Instal...

Страница 8: ...ll corners first 9 If applicable install end cap to end of run 10 After all luminaires have been mounted secure Aircraft Cable Assemblies to luminaire by tightening lower hex nuts All aircraft cables...

Страница 9: ...lead wires from driver Verify wiring diagram before connecting 16 Perform a continuity test before connecting luminaire to power source Refer to page 19 for continuity test step by step 17 Verify dri...

Страница 10: ...make changes or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 10 of 20 ALS500T SWM MI INSTALLATION INSTRUCTIONS Diagram of Assembly Mounting Bracket Assembly Hard Ceiling 5 8 Dryw...

Страница 11: ...Lock Washer and Hex Nut on bolts Leave the assembly loose for now 5 Hang luminaire from mounted Wall Trim and hold in place Have another person slide Mounting Brackets onto luminaire and Wall Trim Ti...

Страница 12: ...lds the luminaire and another person adjusts hex nuts 10 If applicable position the driver in the center of luminaire and secure using set screws by others Do not mount drivers between luminaires Note...

Страница 13: ...et Rail Bracket ALS500T SWM 6 8 Hanging Bracket Rail Bracket For luminaires 1 long use 1 Rail Bracket and 2 Hanging Brackets Install 2 Hanging Brackets 2 from each end of 1 Rail Bracket Align the 1 Ra...

Страница 14: ...1 5 Aircraft Cable Assembly 4 ALS500T SWM 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire N...

Страница 15: ...00T SWM 1 5 4 Mounting Bracket Wall Trim ALS500T SWM 6 8 4 Mounting Bracket Wall Trim For luminaires 1 5 long use 2 Mounting Brackets per luminaire Install each bracket about 4 from each end of lumina...

Страница 16: ...blade for cutting metal Note If applicable remove Connector Blocks from extrusion before cutting 1 Position luminaires together and align the screw of the Male Block to meet the Female Block Tighten...

Страница 17: ...n trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut a 2 se...

Страница 18: ...ormula 409 FEATURES MAINTENANCE SPECIFICATIONS REFLECTANCE 550NM 97 5 0 8 ASTM E1164 L VALUE 98 9 ASTM E308 A VALUE 0 35 0 25 ASTM E308 B VALUE 0 90 0 30 ASTM E308 GLOSS 60 5 0 ASTM D2456 THICKNESS 20...

Страница 19: ...ath is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify the malfunction in the line If there is no conductive path the multimeter w...

Страница 20: ...ctory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a ra...

Отзывы: