background image

Replacement fittings

Complete kit

Valve size

Connection

Union Nut

Tailpiece

Washer

NA20640

½ inch

NPT male

F61008

R31981

F50055

NA20640C

59893A

NA20649

Sweat

NA10002

NA20649C

59904A

NA20646

Press

incl. w/ tailpc

NA16264

NA20647

PEX crimp

F61008

F0000492

NA20647A

NA10484

NA20650

¾ inch

NPT male

F61008

31901A

F50055

NA20650C

59840A

NA20659

Sweat

NA10003

NA20659C

59905A

NA20656

Press

incl. w/ tailpc

NA16264

NA20656A

F0000698

NA10419

NA20657

PEX crimp

F61008

F0000520

NA20657A

NA10485

NA20660

1 inch

NPT male

incl. w/ tailpc

59817A

F50055

NA20660C

59894A

NA20669

Sweat

59834A

NA20669C

59906A

NA20666

Press

NA16266

NA20667

PEX crimp

F61008

F0000521

NA20667A

NA10486

Replacement parts

Replacement body.

 

Complies to 
requirements of NSF/
ANSI 372-2016, low 
lead, as certified by 
ICC-ES, file 
PMG-1360. Certified 
to ASSE 1017/CSA 
B125.3 by ICC-ES, 
file PMG-1357.

ASSE 1017

521101A.........................1" male union thread 

Point of distribution 
mixed temperature 
gauge adaptor fits 
MixCal 521 series 
mixing valves. Threaded 
union mounting 
replaces existing mixed 
outlet with ¾" or 1" 
sweat pipe connection. 

NA10328.........................½" sweat with gauge
NA10056.........................¾" sweat with gauge
NA10058..........................1" sweat with gauge
NA10358 ...............1" union thread with gauge
688003A...Replacement gauge w/ pocket well
R39591............................ Replacement gauge

Removable gauge fits into temperature well. 
Gauge dial is 2” diameter and scale from 
30—210º F. 

9

Содержание MixCal 521410A

Страница 1: ...ems With the unique mixing chamber design MixCal produces very stable mixed water temperture as inlet temperatures and pressures vary Scale formation is minimized with anti scale polymer sliding surfa...

Страница 2: ...s do not endanger people CAUTION To prevent any damage which will cause the electronic mixing valve to not operate correctly treat highly aggressive water before entering the thermostatic mixing valve...

Страница 3: ...ns contenues dans ce manuel il peut ne pas fonctionner correctement et peut mettre en danger l utilisateur ATTENTION S assurer que tous les raccordements sont tanches ATTENTION Les temp ratures de l e...

Страница 4: ...hot or cold water for other uses or variations in the incoming temperature the thermostatic mixing valve automatically regulates the water flow to obtain the required temperature COLD HOT MIX Inlet po...

Страница 5: ...talling a Caleffi MixCal series 521 thermostatic mixing valve the system must be inspected to ensure that it s operating conditions are within the range of the thermostatic mixing valve checking for e...

Страница 6: ...9A and 521619A with integral outlet port temperature gauges provide a time saving temperature setting process to get close to the desired temperture Use of a digital thermometer is recommended for det...

Страница 7: ...with inlet check valves AC models can be used instead of separately installed check valves Refer to principle of operation on page 8 SUPPLY MIX 3 2 4 WATER HEATER Domestic hot water system without rec...

Страница 8: ...port of the mixing valve Ideally this flow should be adjusted so that the rate of heat transfer from the tank to the recirculating loop exactly balances the rate of heat loss from the recirculating l...

Страница 9: ...4A NA20669C 59906A NA20666 Press NA16266 NA20667 PEX crimp F61008 F0000521 NA20667A NA10486 Replacement parts Replacement body Complies to requirements of NSF ANSI 372 2016 low lead as certified by IC...

Страница 10: ...ixing valve will provide a very high level of performance However in some circumstances where the following maintenance schedule is not followed problems may arise Recommended maintenance schedule Tes...

Страница 11: ...2 61 2 4 25 8 521617AC 1 31 4 61 2 83 4 61 8 25 8 At minimum temperature position on adjusting knob Model with integral outlet temperature gauge Code A B C D E F Sweat connections 521409A 1 2 21 4 41...

Страница 12: ...the valve b Starvation of the water supplies at the inlets of the valve c Incorrect commissioning of the valve Restore inlet conditions within the limits of the valve Erratic flow of water from the va...

Отзывы: