background image

7

Replacement fittings

Complete kit

Valve size

Connection

Union Nut

Tailpiece

Washer

consult Caleffi

3

/

8

 inch

compression

F61008/C

F0000718(2)

F50055

NA20640

½ inch

NPT male

R31981

NA20640C (1)

59893A(1)

NA20649

Sweat

NA10002(1)

NA20649C

59904A

NA20647

PEX crimp

F0000492

NA20647C

NA10484(1)

NA20650

¾ inch

NPT male

31901A

NA20650C

59840A(1)

NA20659

Sweat

NA10003

NA20659C

59905A(1)

NA20657

PEX crimp

F0000520

NA20657C

NA10485(1)

NA20660

1 inch

NPT male

incl. w/ tailpc

59817A

NA20660C

59894A(1)

NA20669

Sweat

59834A

NA20669C

59906A(1)

NA20667

PEX crimp

F61008/C

F0000521

NA20667C

NA10486(1)

(1) C = check valve included in tailpiece. Use in inlets.  
(2) Check valve not included: source separately check valve code NA10479.

Replacement parts

Replacement check 
valves for 5213 series 
thermostatic mixing 
valves.

NA10405............ check valve for PEX fittings

R39204... check valve for sweat, NPT fittings

NA10479.................check valve for 521333A

Conical inlet filter 
for 5213 series 
thermostatic mixing 
valves.

F52429..........................................conical filter

Содержание 521352A

Страница 1: ...ater inlet to ensure stable operation 9 F 5 C Minimum flow rate for stable operation 0 5 gpm 2 l min Certifications 1 ASSE 1070 CSA B125 3 2012 certified by ICC ES file PMG 1357 2 NSF ANSI 372 2011 Dr...

Страница 2: ...at such temperatures do not endanger people Leave this manual for the user SAFETY INSTRUCTION This safety alert symbol will be used in this manual to draw attention to safety related instructions When...

Страница 3: ...stpasinstall mis en service et entretenu correctement selon les instructions contenues dans ce manuel il peut ne pas fonctionner correctement et peut mettre en danger l utilisateur ATTENTION S assurer...

Страница 4: ...way as to maintain constant set temperature of the the mixed water at the outlet A thermostatic element is fully immersed into the mixed water This element then contracts or expands causing movement o...

Страница 5: ...ffi 5213 series is a thermostatic mixing valve suitable for single or multiple point of use applications in accordance with installation rules and indications specified in ASSE 1070 standards The syst...

Страница 6: ...5 Thermostatic element 6 Flow conveyor 7 Lower spring 8 Valve body 9 Union washer quantity 3 per valve 10 Union nut quantity 3 per valve 11 Inlet port male tailpiece with integral check valve quantit...

Страница 7: ...F0000520 NA20657C NA10485 1 NA20660 1 inch NPT male incl w tailpc 59817A NA20660C 59894A 1 NA20669 Sweat 59834A NA20669C 59906A 1 NA20667 PEX crimp F61008 C F0000521 NA20667C NA10486 1 1 C check valve...

Страница 8: ...ation is designed and or installed all current legislation is noted e g the maximum distance from the outlet of the valve to any terminal fitting The connecting hot and cold water supplies must be con...

Страница 9: ...lve Isolating valve Strainer check valve Strainer check valve T Pressure reducing valve if required Temperature limiting valve if required HOT SUPPLY COLD SUPPLY MIXED OUTLET MIX MIX HOT COLD MIX MIX...

Страница 10: ...e 2 15 16 5 7 8 5 3 16 3 1 15 16 2 0 521347A PEX crimp 3 6 5 3 5 8 1 15 16 2 0 521357A PEX crimp 3 6 5 3 5 8 1 15 16 2 0 521367A 1 PEX crimp 3 1 16 6 1 8 5 9 16 3 11 16 1 15 16 2 0 521349A sweat 2 11...

Страница 11: ...ign of the cap the temperature setting can be adjusted by removing the cap from the valve body and reversing the cap onto the temperature adjustment spindle Use the following sequence when commissioni...

Страница 12: ...Temperature adjustment View of temperature adjustment Attaching temperature adjustment cap Temperature adjustment cap in place Locking adjustment spindle with locking nut 1 2 3 4 12...

Страница 13: ...by unscrewing the inlet union nuts and carefully pulling apart the connecting piping 2 The built in check valves 11 on the Caleffi 5213 series valves can be accessed in a similar way to 1 to ensure fr...

Страница 14: ...of the valve Restore inlet conditions within the limits of the valve Erratic flow of water from the valve a Insufficient water supplies b Fluctuations in supply pressure and or temperatures c Adverse...

Страница 15: ...15 this page left blank intentionally...

Страница 16: ...Caleffi North America Inc 3883 West Milwaukee Road Milwaukee WI 53208 T 414 238 2360 F 414 238 2366 4 30 18 16...