© Caleffi 11236_iSolar_Plus.mon
us.ind
d
|
34
3. Commissioning
Î
Establish the power supply
During a short initialization phase, the operating control
lamp flashes red and green.
When the controller is commissioned for the first time
or after a reset, it will run a commissioning menu. The
commissioning menu leads the user through the most
important adjustment channels needed for operating the
system.
Operating the commissioning menu:
Î
Enter the channel by pressing button 3
The
symbol flashes.
Î
Adjust the value by pressing buttons 1 and 2
Î
Save the adjustment by pressing button 3 again
The
symbol stops flashing.
Î
Press button 1 or 2 to switch to the next or previous
channel
1
2
3
(OK)
The three push buttons of the BS Plus controller
The commissioning menu consists of the following 6
channels:
1. Language
Î
Adjust the desired menu language in this channel
• dE : German
• En : English
• Fr : French
LANG:
Language selection
Selection: dE, En, Fr
Factory setting: En
2. Unit
Î
Adjust the unit in which temperatures and temperature
differences shall be displayed
UNIT:
Temperature unit selection
Selection: °F, °C
Factory setting: °C
3. Time
Î
Adjust the current time for the real time clock
The hours and minutes have to be adjusted separately, first
the hours, then the minutes.
TIME:
Real time adjustment