3. Commissioning
 

On commissioning you have to adjust primarily the matching system 

System survey:

Arr 1 :  standard solar system 

 

Arr 2 :  solar system with after-heating

1

3

2

backwards

forward

SET

(Selection / Adjustment mode)

Operation cont-
rol  lamp

Arr 1

Arr 2

1. Ac power supply must be activated. The controller passes 
an initialisation phase in which the operating control lamp 
flashes red and green. After having finished the initialisation, 
the controller is in automatic operation with factory set-
tings. The preadjusted system scheme is Arr 1.

2. - select Arr 

  - change into 

-mode (see 2.1)

  - select the system scheme by Arr-characteristics

  - adjustment is saved by pressing button 

Now the controller is ready for operation and should enable 
an optimum operation of the solar system by the factory 
settings made.

4.  Controller parameter and indication channels

4.1  Channel-overview

Legend:

x

Corresponding channel is available.

x*

Corresponding channel is available if the appropriate option 
is activated.

  

 

Corresponding channel is only available if the option heat 
quantity measurement is activated

 (OWMZ).

 

MEDT

The channel antifreeze content (MED%) is only shown if a 
medium other than water or Tyfocor LS / G-LS (MEDT 
0 or 3)
 is used. The adjustment is only appropriate when 
using other types of antifreeze.

  

 

Corresponding channel is only available if the option heat 
quantity measurement is deactivated

 (OWMZ).

Please note: 

 

S3 and S4 are only indicated if sensors are connected.

channel

Arr

specification

page

1

2*

COL

x

x

Temperature collector 1

9

TST

x

Temperature tank 1

9

TSTL

x

Temperature tank 1 below

9

TSTU

x

Temperature tank 1 above

9

S3

x

Temperature sensor 3

9

TRF

Temperature return sensor

9

S4

Temperature sensor 4

9

h P1

x

Operating hours relay 1

9

h P2

x

Operating hours relay 2

9

kWh

Heat quantity kWh

10

MWh

Heat quantity MWh

10

Arr

1-2

System

8

DT O

x

x

Switch-on temperature difference

10

DT F

x

x

Switch-off temperature difference

10

S MX

x

x

Maximum temperature tank 1

10

EM

x

x

emergency temperature collector 1

10

channel

Arr

specification

page

1

2*

OCX

x

x

Option collector cooling collector 1

11

CMX

x*

x*

Maximum temperature collector 1

11

OCN

x

x

Option minimum limitation collector1

11

CMN

x*

x*

Minimun temperature collector 1

11

OCF

x

x

Option antifreeze collector 1

11

CFR

x*

x*

Antifreeze temperature collector 1

11

OREC

x

x

Option reccoling

11

O TC

x

x

Option tube collector

12

AH O

x

Switch-on temp. for thermostat 1

12

AH F

x

Switch-off temp. for thermostat 1

12

OHQM

x

x

Option WMZ

12

FMAX

Maximum flow

12

MEDT

Antifreeze type

10

MED%

MEDT MEDT Antifreeze content

10

HND1

x

x

Manual operation relay 1

12

HND2

x

x

Manual operation relay 2

12

LANG

x

x

Language

12

UNIT

x

x

Change over °FAH / °CEL

12

PROG

XX.XX

Program number

VERS

X.XX

Version number

Содержание iSolar 3

Страница 1: ...Thanks for buying this product Read this manual carefully to get the best perfomance from this unit Mounting Connection Handling Fault localization Examples manual 49005100 49005100...

Страница 2: ...micro films and the storage into electronic systems Editor CALEFFI NORTH AMERICA Inc Important notice We took a lot of care over the texts and drawings of this manual and to the best of our knowledge...

Страница 3: ...4 F Size 172 x 110 x 46 mm Mounting wall mounting mounting into patch panels is possible Display System screen for sys tems visualisation 16 segment display 7 segment display 8 symbols for system stat...

Страница 4: ...lief supports and screws Depending on the version the controller is equipped with 2 relays to which the consumers e g pumps valves etc can be connected Relay 1 18 conductor R1 17 neutral conductor N 1...

Страница 5: ...nsors and after heating The sensor S4 TRF can optionally be used for heat quantity balancing Arr 2 1 2 2 Allocation of clamps for system 2 Symbol Specification S1 collector sensor S2 tank sensor below...

Страница 6: ...d for scrolling forward through the indication menu or to increase the adjustment values The backwards key 2 is accordingly used for the reverse function For adjustment of last indication channel keep...

Страница 7: ...he flow direction or the current bre aking capacity are always shown Heating circuit Tank 1 and 2 with heat exchanger After heating with burner symbol Temperature sensor 2 2 3 System screen only syste...

Страница 8: ...types of antifreeze Corresponding channel is only available if the option heat quantity measurement is deactivated OWMZ Please note S3 and S4 are only indicated if sensors are connected channel Arr s...

Страница 9: ...rating hours of the respective relay h P Full hours are shown on the display The operating hours added up can be reset As soon as one operating hours channel is selected the symbol in permanently show...

Страница 10: ...note Switch on temperature difference DO must be at least 2 Ra higher than the switch off tempe rature difference DF DT O Switch on temperature Adjustment range 2 0 40 0 Ra Factory setting 12 0 DT F...

Страница 11: ...OFF ON Factory setting OFF The minimum collector temperature is a minimum switching temperature which must be exceeded so that the solar pump R1 R2 is switched on The minimum temperature shall avoid a...

Страница 12: ...sed for use of surplus energy or an after heating AH O AH F the thermostat function is used for after heating AH O AH F the thermostat function is used for use of surplus energy On the display is show...

Страница 13: ...47 86 1117 203 1366 95 1136 212 1385 104 1155 221 1404 113 1175 230 1423 122 1194 239 1442 Resistance values of the Pt1000 sensors Check the power supply o k The can fuse of the controller is defectiv...

Страница 14: ...fication no Heat exchanger plugged yes no Cleaning Heat exchanger too small yes New calculation of the dimension no Plausibility control of the option tube collector spe cial function Change Ton and T...

Страница 15: ...up in manual operation yes There is no current check fuses replace them and check power supply The adjusted tempe rature difference for starting the pump is too high choose a matching setting no Is t...

Страница 16: ...tening Sensors Our product range includes high precision platin temperatu re sensors flatscrew sensors ambient temperature sensors indoor temperature sensors cylindrical clip on sensors and irradiatio...

Отзывы: