3. Commissioning
On commissioning you have to adjust primarily the matching system
System survey:
Arr 1 : standard solar system
Arr 2 : solar system with after-heating
1
3
2
backwards
forward
SET
(Selection / Adjustment mode)
Operation cont-
rol lamp
Arr 1
Arr 2
1. Ac power supply must be activated. The controller passes
an initialisation phase in which the operating control lamp
flashes red and green. After having finished the initialisation,
the controller is in automatic operation with factory set-
tings. The preadjusted system scheme is Arr 1.
2. - select Arr
- change into
-mode (see 2.1)
- select the system scheme by Arr-characteristics
- adjustment is saved by pressing button
Now the controller is ready for operation and should enable
an optimum operation of the solar system by the factory
settings made.
4. Controller parameter and indication channels
4.1 Channel-overview
Legend:
x
Corresponding channel is available.
x*
Corresponding channel is available if the appropriate option
is activated.
Corresponding channel is only available if the option heat
quantity measurement is activated
(OWMZ).
MEDT
The channel antifreeze content (MED%) is only shown if a
medium other than water or Tyfocor LS / G-LS (MEDT
0 or 3) is used. The adjustment is only appropriate when
using other types of antifreeze.
Corresponding channel is only available if the option heat
quantity measurement is deactivated
(OWMZ).
Please note:
S3 and S4 are only indicated if sensors are connected.
channel
Arr
specification
page
1
2*
COL
x
x
Temperature collector 1
9
TST
x
Temperature tank 1
9
TSTL
x
Temperature tank 1 below
9
TSTU
x
Temperature tank 1 above
9
S3
x
Temperature sensor 3
9
TRF
Temperature return sensor
9
S4
Temperature sensor 4
9
h P1
x
Operating hours relay 1
9
h P2
x
Operating hours relay 2
9
kWh
Heat quantity kWh
10
MWh
Heat quantity MWh
10
Arr
1-2
System
8
DT O
x
x
Switch-on temperature difference
10
DT F
x
x
Switch-off temperature difference
10
S MX
x
x
Maximum temperature tank 1
10
EM
x
x
emergency temperature collector 1
10
channel
Arr
specification
page
1
2*
OCX
x
x
Option collector cooling collector 1
11
CMX
x*
x*
Maximum temperature collector 1
11
OCN
x
x
Option minimum limitation collector1
11
CMN
x*
x*
Minimun temperature collector 1
11
OCF
x
x
Option antifreeze collector 1
11
CFR
x*
x*
Antifreeze temperature collector 1
11
OREC
x
x
Option reccoling
11
O TC
x
x
Option tube collector
12
AH O
x
Switch-on temp. for thermostat 1
12
AH F
x
Switch-off temp. for thermostat 1
12
OHQM
x
x
Option WMZ
12
FMAX
Maximum flow
12
MEDT
Antifreeze type
10
MED%
MEDT MEDT Antifreeze content
10
HND1
x
x
Manual operation relay 1
12
HND2
x
x
Manual operation relay 2
12
LANG
x
x
Language
12
UNIT
x
x
Change over °FAH / °CEL
12
PROG
XX.XX
Program number
VERS
X.XX
Version number