FILTER CARTRIDGE REMOVAL AND
CLEANING INSTRUCTIONS
Turn the power to the spa off, then proceed as follows:
1. Push down slightly and turn filter basket counter-clockwise to unlock, then
pull the basket and weir out.
2. Carefully pull up the filter cartridge and bring it out of the spa.
3. Rinse cartridge using a garden hose. Rotate and separate filter pleats while
spraying water to remove all debris possible. Let the filter dry and then look
for calcium deposits (scaling) or an oil film. If you find these, you will need to
deep clean your filter cartridge with a “spa filter cleaning” solution to break
down and remove mineral deposits and oils.
4. To return basket and weir, insert and rotate clockwise to lock into position.
Then, turn spa’s power back on.
NOTE:
Replacement filter cartridges are available from your Caldera dealer. Refer
to the back of this manual to determine the appropriate size for your spa.
FIBER OPTICS LIGHT
LIGHT ASSEMBLY REMOVAL AND
REPLACEMENT
WARNING:
The light assembly is extremely hot when operated and will cause
burns if touched. Do Not attempt to touch or replace the light assembly unless it
has been OFF and allowed to cool for at least 30 minutes.
1. Remove the two screws securing the light assembly access cover and
remove the cover.
2. The light assembly is positioned in the light assembly holder. To remove, pull
the light assembly straight up.
3. Remove the light assembly from the light receptacle.
4. Take care to hold the new light assembly by the reflector, DO NOT touch the
light bulb. Carefully position the light assembly and insert (pushing down) into
light assembly holder. Replace with Quartz halogen lamp MR-16, type EYC.
(Fiberstars part number HI-075).
5. Replace light assembly access cover.
DIVERTER VALVE MAINTENANCE
If your spa’s diverter valves become difficult to turn, it is likely that sand or grit has
become lodged inside the valve body. It is very important that this debris is removed as
soon as possible to avoid damage to the valve. To accomplish this, follow this
procedure:
1. Turn off power to the spa.
2. Remove the diverter valve’s handle by pulling upward while rocking it back and
forth.
3. Unscrew the cap ring.
4. Remove the valve body by pulling it upward.
5. Wipe the valve body and the interior walls of the valve clean.
6. Lubricate the valve body with a waterproof lubricant available from your Caldera
dealer.
7. Reassemble the valve and turn on power to the spa.
MAINTENANCE
22
FLOATING WEIR
BASKET
FILTER
CARTRIDGE
SUCTION
LINE
PLEATS
SCREW (2)
LIGHT RECEPTACLE
LIGHT ASSEMBLY
LIGHT ASSEMBLY
HOLDER
LIGHT
ASSEMBLY
ACCESS
COVER
PERIMETER
LIGHT
POWER
MODULE