ELECTRICAL INSTALLATION
10
230 VOLT INSTALLATION
Your spa contains a Control Module designed to operate at 230V, 60Hz. Installation of a 50 amp. dedicated circuit is required. The Control Module must be hard wired
directly to a supply circuit that is protected by a Ground Fault Circuit Interrupter (GFCI).
IMPORTANT NOTE:
All electrical connections to the control Module must be accomplished by a qualified electrician in accordance with the National Electrical Code
and in accordance with any local electrical codes in effect at the time and place of installation.
All electrical connections must be made in accordance with the wiring information contained in this manual and on the back of the field wiring access panel of the
Control Module.
For all permanently connected units not provided with integral disconnecting
means: The electrical supply for this product must include a suitable rated switch or
circuit breaker to open all ungrounded supply conductors to comply with local and
national Electrical Codes. The disconnecting means must be within sight, and
readily accessible to the user of the spa, but installed at least 5 feet (1.5m) from the
spa.
The Control Module requires a 8 AWG copper, four-wire electrical service (Line 1,
Line 2, Neutral and Ground), and requires a minimum supply conductor ampacity of
50 amperes. Failure to connect a neutral line will cause the Control Module to
malfunction and will void the Control Module warranty.
POWER CONNECTION
To connect power to the spa, refer to “230 VOLT WIRING SCHEMATIC DIAGRAM”
and “POWER CONNECTION ACCESS” illustrations above, then proceed with the
following steps:
1. Remove the screws securing the equipment compartment door, lower the door
one inch and remove the door.
2. Remove the screws securing the Control Module wiring access panel, lower the
panel one inch and remove the panel to allow access to the input power wiring.
NOTE:
The 230V wiring diagram is located on the inside of the Control Module
access door.
IMPORTANT:
The following must be followed to properly install the equipment compartment door or wiring access panel.
• Place top of door or panel directly below bartop against the frame of the spa.
• Push bottom of door or panel against the spa frame.
• Slide door or panel upward (pushing in on center of door) until screw holes line up.
• Slightly pull on door or panel, if door remains against the spa then replace the screws.
• If the door does not lock into position, repeat the previous steps.
POWER CONNECTION ACCESS
230V WIRING
ACCESS
CONTROL MODULE
WIRING ACCESS PANEL
EQUIPMENT COMPARTMENT
DOOR
CONTROL MODULE
230V
WIRING
ACCESS (2)
OPENINGS ON
RIGHT& LEFT
HAND SIDE
230V WIRING SCHEMATIC DIAGRAM
Inputs from
transformer
Neutral/Ground Bar
Green (Ground)
Red (Hot)
Black (Hot)
White (Neutral)
White (Neutral)
(Panel Neutral)
(Pigtail)
Red
Black
White
GFCI should be located more than
5 ft. and less than 50 ft. from the spa.
Check your local codes.
NOTE: The 230V wiring diagram is
located on the back of the Control
Module access panel.
*PROVIDED WITH SPA.
NOTE: ALL WIRING SHOULD BE COPPER.
Subpanel*