background image

 

15

is displayed for the duration of Programming Mode. At the end of the 
programmed cook time, the appropriate element will turn "off" and three long 
beeps lasting ½ second "on" ½ second "off" will be heard; the “ON” LED will 
flash for five seconds and the appropriate display will show “0” to indicate 
which burner turned off and to return the unit to programming mode.    

 

Each and every element can be individually programmed with the timer, each 
one having its own time settings and all can run simultaneously. 

 

NOTE: 

The small dot on the bottom right of the digit displaying the cooking 

level of the selected element will illuminate to indicate that the burner is being 
timed. 

d. 

Adjusting or canceling a programmed Cook tim

e: 

At anytime 

during programming of an element (while the “ON” LED flashes), the timer 
can be adjusted to a new time.  To adjust or cancel the Cook time of an active 

element, select the element to be adjusted 

, the timer display will show the 

remaining cooking time, then select Timer by touching the Timer key 

, then 

adjust time using the number keys. To turn the timer off, select “0” twice.  
Bringing the cook time to zero cancels the timer for the selected element (this 
does not turn the burner off, just the timer for the burner). 

e. 

Remembering a programmed Cook tim

e: 

To view the remaining 

cook time of a particular element, just touch the "on" key 

 of the element. 

The remaining cook time is displayed for the 10-second duration of the Initial 
Programming mode (while the 'ON" key LED is flashing). If no time is set for 
a particular element, the display will go blank during the 10-second period. 

f. 

Timed Fan

At any time during programming of the fan (while the fan LED 

flashes and the Fan level is set), the timer can be set to establish the automatic 
fan "off" time. The fan time can be programmed, adjusted, viewed and 
cancelled using the same set of rules as the burner cook time. At the end of the 
programmed fan time, the fan will turn "off", three long beeps lasting ½ second 
"on" ½ second "off" will be heard. NOTE: If a Downdraft is connected to the 
cooktop the Downdraft will not automatically lower when the Fan 
programmed time elapses. 

g. 

Stand-alone Timer

The Timer can be used alone as a reminder.  The 

stand-alone Timer has no effect on the elements or on the fan.   For the stand-
alone timer to be set, neither elements nor the fan should be in Programming 

Mode.  To set the Timer, touch the Timer key 

, then set the desired time, 

using the number keys. The Stand-alone Timer is displayed on a continuous 
basis, except during programming of an element or of the fan. At the end of the 
programmed time, three long beeps lasting ½ second "on" ½ second "off" will 
be heard. The Stand-alone Timer can be adjusted or cancelled. To adjust or 
cancel the Timer, touch the Timer key, then change the Timer settings by using 
the number keys. Bringing the time to '00' cancels the timer. 

h. 

Instant-off/Lock and the Timer

: The timer is affected by Instant-

off/Lock.  When the Lock key                    is touched while elements are ‘on’, 

Содержание SMt364

Страница 1: ...C A L D E R A Please Read and Save for Future Reference Caldera Corporation Waterbury Center VT 05677 USA 800 725 7711 www calderacorp com Fax 800 962 3072...

Страница 2: ......

Страница 3: ...hope you enjoy your purchase REGISTRATION We encourage you to register your cooktop so you may take advantage of our full two year warranty and limited five year warranty should the need ever arise R...

Страница 4: ...cting an Element 11 Selecting a Power Level 12 Selecting Detailed Power 13 Turning Elements Off 4 methods 14 Dual Element Operation 15 Warmer Simmer Burner 16 Recall Feature for Elements 17 Exhaust Op...

Страница 5: ...lectrical appliance near the cooktop be sure that the cord of the appliance does not come into contact with the burner area 5 Do not leave children unattended in an area where appliances are in use Th...

Страница 6: ...t Surface Units To reduce the risk of burns ignition of flammable materials and spillage due to unintentional contact with the utensil the handle of a utensil should be positioned so that it is turned...

Страница 7: ...ner off a touch the corresponding or b touch the corresponding to enter programming then the 0 Using the timer by itself touch the hourglass then the digits that represent the minutes you want to set...

Страница 8: ...burner to indicate that the burner is too hot to touch The lights will remain on until the glass is safe to touch even after the burner has been turned off Limit Switches Limit switches are located i...

Страница 9: ...ner Only is 1000W Rear Right 1500W Rear Left 1500W Downdraft Features 550 cfm with a built in blower and matching glass top controlled from your cooktop Energy Tips Energy Saving Tips Place a utensil...

Страница 10: ...her than a sugary substance is on the hot zone do not clean until the unit is completely cooled down and follow the instructions below Clean up for burned on spillovers If you accidentally melt anythi...

Страница 11: ...Sequence Other Burner Functions Unlock 1 Select Burner 2 Instant Power 3 Detailed Power 4 Timer 5 Timer minutes 6 Fan 7 Fan level 8 Burner Off 9 Switch To Inner Burner 10 Select Burner Recall 4 11 Di...

Страница 12: ...Instant Off locking the unit will de energize all active burners immediately 4 LOCK MODE When the cooktop is in Lock Mode Lock LED is off the burners may not be operated The downdraft fan and the tim...

Страница 13: ...el or timer key is not touched for an uninterrupted period of 10 seconds the programming attempt will be canceled A touch of any other element symbol will cause that element to be selected while the p...

Страница 14: ...unctions will not work no beeps no LED s It will also determine if it is hooked to a downdraft or to a hood Hoods may not yet be available 18 DOWNDRAFT CONTROLS Fan speed Up Down control The Downdraft...

Страница 15: ...2 3 H or Recall will turn the fan on to the selected level NOTE 2 The fan and the light can be independently controlled at any time regardless of the status of either of them 20 TIMER DESCRIPTION FUNC...

Страница 16: ...is displayed for the 10 second duration of the Initial Programming mode while the ON key LED is flashing If no time is set for a particular element the display will go blank during the 10 second perio...

Страница 17: ...ated although all keys are functioning and the display shows the selections as if the burners were active SAFE mode is a handy tool for demonstration purposes it allows demonstration of the control fe...

Страница 18: ...RROR E3 A thermistor error code will be generated if the on board thermistor is short or open The thermistor error will cause all active elements to shut off The cooling fan will run for an additional...

Страница 19: ...number has been altered or removed from the product REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER CALDERA CORPORATION SHALL NOT BE LIABLE FOR ANY INCIDE...

Страница 20: ...19 Part C 14 03 0 1 Revised 10 28 05...

Отзывы: