13
c) Locking the cooktop by holding the Lock key for a period of 1 second will turn all
active elements off.
d) While in Timed Cooking (see paragraph 20), at the end of the programmed cook time, the
appropriate element will turn off.
14. DUAL ELEMENT OPERATION
The Dual element starts by default in dual mode. If the dual element is selected it will begin in
dual mode and the LED will come on under the double ring of the toggle / indicator.
The
element will maintain its power setting while toggling between the inner and both burners.
15. WARMER/SIMMER BURNER
The warmer / simmer element is meant to offer a wide selection (44 levels) of low power levels
ranging from a mere 8.6 Watts and up to a maximum of 375.0 Watts.
16. LONG TERM INDIVIDUAL ELEMENT RECALL
At all times when the cooktop is in normal operation, if any burner "On"
key is selected,
followed by the “Recall” key
, the selected burner will activate whatever its last setting was
regardless of the time elapsed. Loss of power from a power outage will return all units to zero.
17. EXHAUST OPTIONS
The cooktop will determine if there is or is not a connection to an exhaust device. If there is not a
connection the fan key and fan functions will not work (no beeps, no LED’s). It will also
determine if it is hooked to a downdraft or to a hood. (Hoods may not yet be available.)
18. DOWNDRAFT CONTROLS (Fan speed & Up/Down control)
The Downdraft is activated from the cooktop. There is one Fan touch key
and an LED is
located beneath the Fan touch key. Touching
for 1.5 second will raise the Downdraft. From
the “up” position, the Fan LED then flashes for a period of 10 seconds, indicating that the Fan is
in Initial Programming Mode. Touching one of the L, 1, 2, 3,…H level keys within the 10-
second period will start the fan speed at the corresponding level. The last selected Fan level is
then stored in memory for further recall. Touching zero while in Programming Mode shuts the
fan off but leaves it raised. This is useful for cleaning. Touching the Fan key for 1.5 seconds
shuts the Fan "off" and lowers the Downdraft or, if the Fan is already 'off', the 1.5 second touch
simply lowers the downdraft. Subsequent 1.5-second touch to the Fan touch pad will raise the
Downdraft. If the RECALL key is touched during programming mode, the Fan will adopt the
last selected speed level as stored in memory. A single quick touch to the fan key while the fan
is operating will re-enter Programming mode and enable the fan speed to be changed. The
Timer
can then be invoked during "programming mode” to program a timed shut off (see
paragraph 20).
Содержание SMt364
Страница 2: ......