U
ser
'
s
G
Uide
— 7
(cont’d)
milli- —
Used with Watts, Amps, Volts, and
Volt-Amps keys to identify “milli-” values.
amps —
Enters or calculates Amps (using Volts
and VA or Watts).
Volts —
Enters or calculates Volts (using
Amps, HPth, and VA or Watts). Default value
is 240 Volts.
Volt-amps —
Enters or calculates Volt-Amps
(using Amps, Volts and Horsepower or Watts).
Watts —
Enters or calculates Watts (using Amps,
Volts, and VA or Horsepower).
Dc amps (idc) —
Enters or calculates DC Amps
(using DC Volts and Resistance).
Dc Volts (Vdc) —
Enters or calculates DC Volts
(using DC Amps and Resistance).
Dc resistance (r) —
Calculates and displays
DC Resistance in Ohms (using DC Volts and
DC Amps).
power Factor (pF%) —
Enters or calculates
Power Factor percentage (based on Watts
and VA). Default value is 100%. Entered or
calculated Power Factors greater than 100%
will result in an error.
theoretical Horsepower —
Enters or calculates
Theoretical Horsepower (based on Amps, VA,
Watts, Efficiency%, PF%, and/or Volts). 1.0 HPth
correlates to 746 Watts at 100% Efficiency.