36 — ElectriCalc Pro
Finding Synchronous Motor
Horsepower
A synchronous motor is defined as
having a 27 amp load on a 240 volt, 3Ø
circuit. What is its horsepower?
Steps
Keystrokes
Display
Reset calculator
[On/C]
0.
Set to synch.
[Set] [8]
0. SYNC
Enter volts
240 [Volts]
240. VOLT
Enter amps
27 [Amps]
27. AMPS
Solve for Hp
[HPmotor]
25. HP SYNC
Ampacity Wire Sizing
The required wire size of a service
conductor can be determined based on
the specified electrical requirements
and the [WireSz] key. The wire size is
automatically recalculated whenever
the wire insulation (temperature) ratings
or wire material (copper or aluminum)
types are revised. Wire sizing is based
on the requirements defined in NEC
Tables 310-16 and 310-17.
5060-UG-B-Composite 4/4/03 12:37 PM Page 38