User’s Guide — 25
♦
Third Press
Shows fill percentage for the calculated
conduit size as determined by Table 1,
Chapter 9. Displays: COND FILL %.
♦
Fourth Press
Shows the total wire area for all entered
wires. Displays: FILL TTL WIRE AREA.
♦
Fifth Press
Shows remaining fill area. This value
may be negative if all wires are the
same size due to Note 7 in NEC Chap-
ter 9, Table 1.
Displays: REM WIRE AREA.
[Set] [CondSz] — Conduit Type
♦
First Press
Displays the currently selected conduit
type.
♦
Second Press
Subsequent presses will display and
select the next conduit type from this
list: 1) EMT 2) ENT 3) FMC 4) IMC
5) LFNB 6) LFNA 7) LFMC 8) RMC
9) P-80 10) P-40 11) P-A 12) P- EB.
To select a specific conduit type, enter
the corresponding number of the con-
duit and then press [Set] [CondSz]. If
you press this keystroke without enter-
ing a number, the calculator will switch
to the next conduit type on the list.
5060-UG-B-Composite 4/4/03 12:37 PM Page 27