ITC 220 Base Station, Locomotive & Wayside Radio Transceiver Field Service Guide PN 0046300120 Rev. A
| Page 29
4.
The
Configure Port
dialog window opens.
Figure 20 XtermW Configure Port window with settings for the MAINT port
5.
Set
Select Port Type
to
TCP/IP
.
6.
Set the
Protocol
to
Stream
.
7.
Set
TCP/IP Host
and
Por
t to the IP address and port for the Ethernet port you are connecting to.
The default IP address for the Transceiver
MAINT
port is
192.168.255.201
.
The default IP address for the Transceiver
LAN
port is
10.255.255.201
.
8.
Set the
Device Type
and the rest of the settings in the window as shown in the figure.
9.
Click
OK
to save the connection profile and connect to the specified Ethernet port.
To use a previously-saved connection profile in the future, open
XtermW
, and from the
File
menu, select
Open
, and
then select the connection profile to use.
5.4.4
VERIFY THAT THE MAINT AND LAN ETHERNET PORTS ARE OPERATIONAL
Use the preceding procedures to configure Ethernet ports of the test computer for connection to the Transceiver
MAINT and LAN ports, and connect the test computer to each these ports. The test computer should display an active
network connection on both ports (indicated in the System Tray in Windows XP) within 60 seconds.