Page 32
Revised 01/01/04
(Flashing)
Self-Diagnostics
Display Messages for 5000 Electronic Spas
“Overheat” The spa has
shut down. Either the spa has
reached a temperature of
112F˚ or the High-limit sen-
sor has detected overheating
in the heater manifold.
DO NOT ENTER THE SPA WATER.
Remove the spa cover and let the water
cool. At 110˚F the spa should automati-
cally reset. If the spa does not automati-
cally reset, press any pad on the topside
control panel. If the spa still won’t reset,
turn off the power and call your local
authorized service center.
“FL” A pressure switch has
detected a loss of water flow.
Check the filter for debris.
If it’s dirty, clean it. (See page 14 for
cleaning instructions) If the problem per-
sist, call your local authorized service
center.
“Sensor” Spa has shut down.
The Hi-limit/Temperature sen-
sor has malfunctioned.
Call your local authorized
service center.
“Economy Heating Mode” When
flashing alternately with the water
temperature, your spa is in the
Economy Heating Mode.
This message does not indicate the need for
service. For more information, see the
Standard and Economy
Modes Section on page 29.
“Safety” Spa has shut down.
The safety suction system
has activated.
Check the drains and filters for debris
or obstructions. To reset the system,
press any pad on the topside control
panel.
“LED’s” These LED lights are
used to inform you that the corre-
sponding feature is operational.
These LED’s are not service indicators.
No action is required.
13
Содержание 1100 Electronic Series
Страница 12: ...10 ...
Страница 78: ...10 ...
Страница 118: ...10 ...
Страница 161: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Страница 219: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Страница 282: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...