background image

5

maximum  

ceiling  

height  

10ft

minimum  

clearance  

15”

minimum clearance 76”

48 1/2” x 31”

rung  

spacing  

11 3/4”

rung width  

20 3/4”

frame 

width  

30 3/4”

DIMENSIONS

maximum  

ceiling  

height  

14ft

minimum  

clearance  

19”

minimum clearance 90 1/2”

64 1/4” x 31”

rung  

spacing  

11 3/4”

rung width  

20 3/4”

frame 

width  

30 3/4”

DIMENSIONS

RL62

RL63

DISTRIBUTED BY © CAI Safety Systems | (951) 465-7386 | https://caisafety.com | [email protected]

Содержание RL60 Series

Страница 1: ...INSTALLATION MANUAL FOLD DOWN LADDERS Distributed by CAI Safety Systems DISTRIBUTED BY CAI Safety Systems 951 465 7386 https caisafety com webstore caisafety com...

Страница 2: ...personnel 10 Appropriate temporary access and safety equipment must be used during installation such as platform ladders or scaffolding and fall protection anchor points 11 In case of emergency acces...

Страница 3: ...mper with or make alterations to system components without manufacturer s consent 6 This system is not to be used for tethering or lifting machinery or equipment 7 RL60 Series Ladders must not be used...

Страница 4: ...ioration or damage to the system or equipment must be reported to the person in control of the workplace and relevant correction action undertaken 4 Fixing and support structure attachment and suitabi...

Страница 5: ...rung width 20 3 4 frame width 30 3 4 DIMENSIONS maximum ceiling height 14ft minimum clearance 19 minimum clearance 90 1 2 64 1 4 x 31 rung spacing 11 3 4 rung width 20 3 4 frame width 30 3 4 DIMENSIO...

Страница 6: ...3 4 137 3 4 48 3 4 63 23 3 4 72 141 3 4 50 78 3 4 28 76 1 2 145 3 4 51 1 4 94 1 2 32 1 4 80 3 4 149 1 2 52 1 2 110 1 4 37 85 153 1 2 53 1 2 118 38 1 4 87 157 1 2 54 3 4 N A N A N A 161 1 2 56 N A N A...

Страница 7: ...ixing Pack FIXINGS 4x M12 1 1 8 Purlin Bolt Screws 12x 12G 1 1 8 Series 500 Tek Screws 50x 12G 3 4 Self Drilling Tek Screws AL732 4 x 2 x 1 2 Angle 63 L QTY 2 AL731 2 x 2 x 1 2 Angle QTY 4 Suspension...

Страница 8: ...x temporarily with 2 12G 1 tek screws Once finally aligned and positioned drill 2 1 2 holes through purlin hanger and purlin Insert 2 M12 1 2 purlin bolts tighten securely Determine correct mounting p...

Страница 9: ...ort frame Then bolt the splice sections and the frame to the droppers Fix with 1 M8 x 2 1 4 cup head bolts Fasten a 3 4 tek screw through the frame into the splice section to lock in position 34 M8 x...

Страница 10: ...from the purlins without having to use the main support angles Determine direction of fold down ladder in relation to direction of purlins If not in line with purlins see below Rear bracing to be fix...

Страница 11: ...Ladder Body 3rd Stage 2x Adjustable Splice Feet 1x Pull Stick 1x Eye Hook 1x Fixing Pack FIXINGS 6x M8 1 4 Setscrew Sets 4x M10 3 4 Bolt Nyloc Nut Sets 12x M10 Washers 4x 12G 3 4 Self Drilling Tek Sc...

Страница 12: ...onnected appropriately by authorized qualified personnel Mark out and cut opening in ceiling The above ceiling cutout dimensions allow for frame clearance including a 1 cover on all four sides provide...

Страница 13: ...ace second and third ladder sections or ladder assembly aside Be careful not to scratch pre finished surface of fold down ladder frame and door Use packing box as protective surface 9 DISTRIBUTED BY C...

Страница 14: ...fold down ladder frame with 8 M5 x 1 2 countersunk bolts 2 bolts per clip Ensure ladder is facing correct direction Support frame must be square Failure to do so will cause ladder door closure diffic...

Страница 15: ...per side When ladder closes top of ladder protrudes 1 3 4 beyond ladder frame Allow 2 gap to ensure ladder assembly does not impact on the void end Insert packer to close gap if aesthetically required...

Страница 16: ...y Measure distance from bottom of second stage ladder section and floor and then subtract 2 from adjustable feet insertion Cut third stage ladder section to suit required height Install third stage la...

Страница 17: ...s are fully unfolded Adjust feet to suit floor level Once adjusted correctly fix in place using 2 12G x 3 4 tek screws per foot Ladder feet must be positioned to ensure 500lbs working load is fully su...

Страница 18: ...locate the hook onto the top end of the tube Pull down the Vista ladder half way down towards you until you can safely pull the remainder of the ladder by hand and remove the pull stick from the tube...

Страница 19: ...eiling Ladder 47 1 2 or 94 1 2 2x Fixing Angles 1x Fixing Pack FIXINGS 2x M8 1 4 Cup Bolt Sets 4x M8 2 1 4 Cup Bolt Sets 2x RHS Plastic End Caps DISTRIBUTED BY CAI Safety Systems 951 465 7386 https ca...

Страница 20: ...port frame using 2 12G x 3 4 tek screws 1 per bracket Fix ladder fixing bracket to front purlin hanger or to purlin trimmers using 2 M8 x 1 cup bolt sets 20 21 DISTRIBUTED BY CAI Safety Systems 951 46...

Страница 21: ...ladder stiles Insert 2 M8 x 2 1 4 cup bolts through holes tighten securley Fix ceiling ladder to base support angle using 2 M8 x 2 1 4 cup bolts 1 per bracket Distance from top of bottom rung of ceil...

Страница 22: ...require a suspension kit attached to roof structure above 3 Ladder fixing to structure Ensure minimum 4 M8 bolt sets or 6 12G screws securing ladder frame to structure 4 Ladder bodies assembly Ensure...

Страница 23: ...3 4 5 5 3 4 The checklist below outlines key checking criteria required to ensure the safe use of this system Any item of concern not shown on the checklist must be noted on the maintenance report and...

Страница 24: ...Distributed by CAI Safety Systems 1609 S Grove Ave Ste 104 Ontario CA 91761 USA Phone 951 465 7386 Fax 951 405 2796 Email webstore caisafety com Website https caisafety com...

Отзывы: