CT-100/CT-150 Series User’s Manual 

 

  7 

 

 
 
 
Read over the instruction manual carefully before using the instrument. 
The following precautions should be strictly observed before using the CT-100/CT-
150 DCCTs: 
 

 

 

WARNING 

 

Do  not  use  this  product  in  any  manner  not 
specified  by  the  manufacturer.  The  protective 
features  of this product  may be impaired if it is 
used in a manner not specified in this manual. 

 

 

 

Do not use the device if it is damaged. Before you 
use the device, inspect the instrument for possible 
cracks or breaks before each use. 

 

 

 

Do not operate the device around explosives gas, 
vapor or dust. 

 

 

 

Always use the device with the cables provided. 

 

 

 

Turn  off  the  device  before  establishing  any 
connection. 

 

 

 

Do not operate the device with the cover removed 
or loosened. 

 

 

 

Do  not  install  substitute  parts  or  perform  any 
unauthorized modification to the product. 

 

 

 

Return the product to the manufacturer for service 
and  repair  to  ensure  that  safety  features  are 
maintained 

 

 

 

CAUTION

 

 

This instrument is designed for indoor use and in 
area with low condensation. 

 

 

 

 

Содержание Flucs CT -100

Страница 1: ...DC Current Transducers CT 100 CT 150 User s Manual All Rights Reserved CAEN ELS s r l Rev 1 8 November 2022 PRECISION CURRENT TRANSDUCERS...

Страница 2: ...CT 100 CT 150 Series User s Manual CAEN ELS s r l Via Vetraia 11 55049 Viareggio LU Italy Mail info caenels com Web www caenels com...

Страница 3: ...Pinout 14 2 2 MOUNTING 15 2 3 PRIMARY CURRENT PATH 16 2 4 FULL SCALE CURRENT 16 2 5 SECONDARY SIDE SIGNALS 17 2 5 1 Power Supply 17 2 5 2 Secondary Current 17 2 5 3 Voltage Output V versions only 18 2...

Страница 4: ...ed external shunt values 1 3 July 8th 2016 Added data to technical specifications 1 4 September 20th 2017 Added insulation characteristics 1 5 March 12th 2018 Added information on GND connection 1 6 M...

Страница 5: ...ting any part of the instrument WARNING Do NOT open the boxes CAEN ELS d o o declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of...

Страница 6: ...s one to be used with the current output DCCTs and one with the voltage output ones the PS1212V is shown in the previous image Product Code Description WPS1215VXAAA PS1215V AC DC Single Output Dual Vo...

Страница 7: ...it is damaged Before you use the device inspect the instrument for possible cracks or breaks before each use Do not operate the device around explosives gas vapor or dust Always use the device with th...

Страница 8: ...eral environmental requirements for a correct operation of the instrument Environmental Conditions Requirements Operating Temperature 0 C to 45 C Operating Humidity 30 to 85 RH non condensing Storage...

Страница 9: ...150 transducers can be chosen between two different versions standard secondary current output or buffered voltage output low temperature coefficient shunt resistor and low noise amplifier are embedde...

Страница 10: ...trial and automotive fields Front view of a CT 100 CT 150 current transducer in its DB 9 connector version is presented in Figure 1 Figure 1 front view of a CT 100 CT 150 current transducer with DB 9...

Страница 11: ...100PXAAAA CT 100 P 100 A Primary Current 7 pin PCB connector WCT100VCXAAA CT 100V C 100 A Primary Current DB 9 connector Voltage Output WCT100VPXAAA CT 100V P 100 A Primary Current 7 pin PCB connector...

Страница 12: ...he casing that indicates the verse of positive primary current measurement This arrow can be seen in Figure 3 top view of a CT 100 CT 150 mechanical enclosure Figure 3 embossed arrow indicating the ve...

Страница 13: ...the C versions are presented in Table 2 These two versions have current or voltage output pins and their signal returns Pin CT 100 C or CT 150 C Current Output CT 100V C or CT 150V C Voltage Output 1...

Страница 14: ...The pinout for the P versions are presented in Table 3 These two versions have alternative current or voltage output signals and their respective returns on the same pins Pin CT 100 P or CT 150 P Curr...

Страница 15: ...nt 4 hole patterns placed in different sides of the mechanical case Four holes are present on the bottom of the device as indicated in the following Figure 6 Figure 6 Bottom mounting holes pattern Oth...

Страница 16: ...current is routed over one side of the DCCT head the Magnetic flux density is higher in the area between the U path If the current path return is split in two or more paths over the DCCT Head the mag...

Страница 17: ...ase note that not all of them are present on all versions of the DB 9 connector The same signals for the P version are found from pins 4 to 7 of the through hole 7 position strip 2 5 1 Power Supply Su...

Страница 18: ...for the P is referred to VO RET pin 7 on both C and P options and the behavior is as follows For CT 100 series 10V output if the primary current is 100A 10V output if the primary current is 100A For...

Страница 19: ...K signal is not internally connected to the ground potential and can be connected to an external reference potential A green LED is also present on the front side of the DCCT indicating the correct op...

Страница 20: ...3 3V supply and the OK_SIGNAL is referred to DGND potential which can be the same or different from the GND potential on which the CT device is supplied from The OK_SIGNAL is found to be at low level...

Страница 21: ...e ordering code is formatted as follows C T X X X Y Z NOTE fields characters shaded in grey color are fixed Example the DC current transducer version CT 100V C has a full scale measurable current of 1...

Страница 22: ...econdary Current IS RMS 71 mA External Shunt Resistor Value RS 0 40 0 40 Small Signal Bandwidth 3 dB typ BW 500 kHz 200 kHz V version 300 kHz 200 kHz V version Equivalent Input Noise Bandwidth 1 ppm F...

Страница 23: ...ELS PS1215 power supply Table 4 Technical Specification 4 1 Equivalent Input Noise The typical equivalent input noise of the CT 100 CT 150 transducers is hereafter presented as a function of the measu...

Страница 24: ...the current output versions is shown hereafter in the following chart Figure 14 CT 100 maximum external shunt resistor Current version only 0 1 2 3 4 5 6 7 8 2 20 200 2000 20000 Equivalent Input Nois...

Страница 25: ...tions over voltage cat III pollution degree 2 Rated insulation voltage RMS basic insulation 1000 V EN 50178 conditions over voltage cat III pollution degree 2 Rated insulation voltage RMS reinforced i...

Страница 26: ...he mechanical dimensions of the CT 100 CT 150 Series DC Current Transducers are hereafter presented all dimensions are in mm 5 1 CT 100 CT 150 Series C version Figure 16 Mechanical drawings for CT 100...

Страница 27: ...CT 100 CT 150 Series User s Manual Mechanical Dimensions 27 5 2 CT 100 CT 150 P version Figure 17 Mechanical drawings for CT 100 CT 150 Series P Version...

Страница 28: ...DC User s Manual...

Отзывы: