Technical Specifications
Technical Specifications for current transducers of the CT-100/CT-150 Series
(both current and voltage output versions) are herein presented.
Technical Specifications
CT-100
CT-150
Current Transformation
Ratio - N
1:1000
1:1500
Maximum DC Primary
Current - I
P(DC)
±100 A
±150 A
Maximum RMS Primary
Current - I
P(RMS)
71 A
106 A
Current Polarity
Bipolar
Maximum DC Secondary
Current - I
S(DC)
±100 mA
Maximum RMS Secondary
Current - I
S(RMS)
71 mA
External Shunt Resistor
Value - R
S
0…40
Ω
0…
40
Ω
Small Signal Bandwidth
(±3 dB)
–
typ. BW
> 500 kHz
> 200 kHz ("V"-version)
> 300 kHz
> 200 kHz ("V"-version)
Equivalent Input Noise
(@Bandwidth)
*
< 1 ppm/FS @ 200Hz
< 10 ppm/FS @ 50 kHz
Output Voltage
("V"-version) - V
OUT
±10 V
Output Voltage Gain
("V"-version) - V
OUT
/I
P(DC)
1/10 V/A
1/15 V/A
Maximum Output Current
("V"-version)
±15 mA
Temperature Coefficient - TC
< 0.5 ppm/°C
typ. < 2 ppm/°C ("V"-version)
Non-Linearity
< 5 ppm
< 15 ppm ("V"-version)
Induction into Primary
(0-100 kHz) typ.
35 µV (RMS)
Offset (with factory
calibration)
*
< 10 ppm/FS
Protection Signal
OK Status
Supply Voltage (± 6%)
±15 V
Current Consumption
50 mA + I
S