![CAENels Flucs CT -100 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/caenels/flucs-ct-100/flucs-ct-100_user-manual_3283200025.webp)
CT-100/CT-150
Series User’s Manual
25
Figure 15:
CT-150 maximum external shunt resistor (
Current
version only)
4.3
Insulation characteristics
In the following table are represented the insulation characteristics of the CT-
100, CT-150 current transducers.
Parameter
Value
Reference
Rated insulation voltage (RMS),
basic insulation
2000 V
IEC 61010-1 conditions
- over voltage cat III
- pollution degree 2
Rated insulation voltage (RMS),
reinforced insulation
600 V
IEC 61010-1 conditions
- over voltage cat III
- pollution degree 2
Rated insulation voltage (RMS),
basic insulation
1000 V
EN 50178 conditions
- over voltage cat III
- pollution degree 2
Rated insulation voltage (RMS),
reinforced insulation
600 V
EN 50178 conditions
- over voltage cat III
- pollution degree 2
RMS voltage for AC insulation test,
50/60 Hz, 1 min
5.4 kV
Between primary and
sec shield
Clearance (primary
–
secondary)
11 mm
Shorter distance path
Table 6:
Insulation characteristics
The voltage insulation category could be improved, if insulated cable is used for
the primary circuit.
60
75
90
105
120
135
150
165
180
195
210
225
240
255
270
285
300
30
40
50
60
70
80
90
100
M
axi
m
u
m
Sh
u
n
t
R
e
si
sto
r [
Ω
]
I
S
[mA]
CT-150
Содержание Flucs CT -100