A927ZET Technical Information Manual
32
Sample Time
Sample Time register is used to define the Sampling Time of the sensor expressed in seconds. At the same time it is the
resolution of logging feature. The Number should be a multiple of 8 (minimum sampling time). The maximum sampling
time is 65535 sec ( ≈ 18 hours). This register can be written only when logging is turned off.
Temperature Sample Time (int) [15:00]
User
Bank:11b
Word addr: 15h
R/W
Temperature Sample Time (ext) [15:00]
User
Bank:11b
Word addr: 1025h
R/W
Battery Sample Time [15:00]
User
Bank:11b
Word addr: 2035h
R/W
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Sample Time [15:00]
High Threshold / Low Threshold
HighThreshold / LowThreshold registers define the allowed (or normal) range of sensor value. Sensor can be configured
to monitor when sensor value is inside/outside these limits (see Fig. 3.1: A927ZET High/Low Threshold monitoring).
Temperature Low Threshold (int) [15:00]
User
Bank:11b
Word addr: 16h
R/W
Temperature Low Threshold (ext) [15:00]
User
Bank:11b
Word addr: 1026h
R/W
Battery Low Threshold [15:00]
User
Bank:11b
Word addr: 2036h
R/W
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Low Threshold [15:00]
Temperature High Threshold (int) [15:00]
User
Bank:11b
Word addr: 17h
R/W
Temperature High Threshold (ext) [15:00]
User
Bank:11b
Word addr: 1027h
R/W
Battery High Threshold [15:00]
User
Bank:11b
Word addr: 2037h
R/W
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
High Threshold [15:00]