A927ZET Technical Information Manual
25
A927ZET NoS description
NoS – Number of available sensors [15:00]
User
Bank:11b
Word addr: 0h
R only
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Number of Sensors [15:00]
Number of sensors [15:00]
value:2
Temperature, Battery monitor
A927ZET SAM Entry description
Number of available sensors (NoS) is stored first followed by SAM entries for each sensor. NoS is stored as 16bit
unsigned integer value. Each SAM entry contains the pointer to the beginning of the allocated memory and memory
range of that specific sensor. All the information related to this sensor is in the range declared into SAM entry field
including characteristics, configuration and data registers.
Each sensor has its own SAM entry in Sensor Address Map.
Temperature SAM Entry (int) [47:00]
User
Bank:11b
Word addr: 1h
R only
Temperature SAM Entry (ext) [47:00]
User
Bank:11b
Word addr: 4h
R only
Battery SAM Entry [47:00]
User
Bank:11b
Word addr: 7h
R only
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
RFU
MBS
Sensor Address [23:16]
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Sensor Address [15:00]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Memory Range [15:00]
Temperature
Battery
MBS – Memory Bank Selector
3
3
Sensor Address [23:00]
Ah (int)
202Ah
101Ah (ext)
Memory Range [15:00]
1010h (int)
110h
1010h (ext)