FAST-Bi-1K5 – User’s Manual
16
•
NORMAL
: the update of the set-point (current or voltage) is performed as
soon as a new set-point is received via remote control, local control or fast
interface;
•
WAVEFORM
: the update of the set-point is performed on a specific timing
(defined as a “waveform” attribute, more information on the
Waveform
section) and it is done internally;
•
ANALOG INPUT
: the PS is controlled by an external signal that is fed to
the rear BNC connector. The PS acts as a C.C. or C.V. generator depending
on the Regulation Mode. Please note that this mode of operation is possible
only on PSs having installed the analog input SMA connector
(FB1K5OPT0001 ordering option).
•
SFP
: this interface allows controlling the PS via a proprietary protocol over
the SFP/SFP+ interfaces (optical or electrical) in case of very fast
applications. Update rates up to 100 kHz are reachable using this
communication channel.
Please note that the last two operation modes are available only with the
FB1K5OPT0001 option at the time of purchase.