Troubleshooting

Situation

Points to check and how to handle

Reference 
pages

There is no air volume.
The air volume is too weak.

Is the power cord plugged into the wall outlet correctly?

 

Plug the power cord into the wall outlet.

8

Did you remove the deodorizing/dust collecting/anti-bacterial filter from the 
polythene bag when you installed it?

 

Please remove the deodorizing/dust collecting/anti-bacterial filter 

from the polythene bag and install it in the unit properly.

6-7

Is the air inlet/air outlet dirty?

 

Clean the unit and remove dirt from the air inlet and air outlet on the 

unit. If the performance does not improve even after cleaning, replace 
the deodorizing/dust collecting/anti-bacterial filter with a new one.

9

~

10

Is the deodorizing/dust collecting/anti-bacterial filter installed upside 
down?

 

Make sure that the top and bottom positions are correct.

6-7

The indicators/buttons on the 
control panel are flashing.

Is the cover closed properly?

 

Check whether the deodorizing/dust collecting/anti-bacterial filter is 

installed properly and firmly close the cover.

7

The odor and dust monitor 
remains red.

The dust and odor sensors may react to changes in temperature and 
humidity or gas from sprays and the like.

 

Wait a few minutes and make sure the odor and dust monitor 

changes to yellow or blue.

5

Is the dust sensor dirty?

 

Clean and remove dirt from the dust sensor.

* In a place where odor substance is generated, such as rooms where 
carpentry work has been performed, etc, the odor and dust sensor 
may remain lit in red or yellow.

9

The odor and dust monitor 
remains blue.

Is the unit placed in a location with bad air circulation, such as in an area 
completely surrounded by something?

 

Make sure the unit is located at least 30 cm away from walls, 

furniture, curtains, etc. on both sides, the front, back, and above.

3

Is the dust sensor dirty?

 

Clean and remove dirt from the dust sensor.

9

Have five minutes already elapsed after turning on the unit?

 

For the first five minutes after turning the power on, the sensors are 

initializing and the unit cannot indicate the exact air condition. Wait 
for a while and see whether the odor and dust monitor changes to a 
different color.

Содержание AP-C200

Страница 1: ...ons 3 Installing the Unit 4 Parts and Functions 6 Installing the Deodorizing Dust Collecting Anti Bacterial Filter 8 How to Operate 9 Maintenance 11 Troubleshooting 13 Specifications Air Purifier AP C...

Страница 2: ......

Страница 3: ...ce center Do not use the unit in the following locations In areas with flammable gas or places with metal dust It may lead to the gas catching on fire igniting or fuming due to dust being sucked into...

Страница 4: ...o stop operation and unplug the power plug Leaving the power plug in the outlet may cause electric shock or injury Do not sit or stand on the unit Falling down from the unit or toppling may cause inju...

Страница 5: ...or malfunction of the unit Do not use the unit near a TV or radio It may cause distortion of video images or noise Place the unit at least 1m away from a TV or radio Also using the same wall outlet as...

Страница 6: ...ti bacterial filter removes the dust and odor particulates page 6 10 Odor and dust monitor indicates the room air quality in blue yellow and red page 5 Control panel page 8 Handle When carrying the un...

Страница 7: ...nd indicates the air environment in the room with the colors blue yellow and red Odor and dust monitor Air environment of room Blue Clean Yellow Slightly polluted Red Polluted Odor and dust sensors De...

Страница 8: ...cterial Filter 1 2 c Attach the Filter Start Date label on the filter Write the filter use start date on the label then attach it onto the side printed TOP on the filter XX XXXX XXXX Filter Start Date...

Страница 9: ...7 Close the cover With the cover switch slid down attach the cover onto the unit Jan 1 2015 Note Again make sure the top and bottom position of the filter is correct before attaching the cover 3...

Страница 10: ...cators and buttons on the control panel along with the odor and dust monitor will momentarily light up then turn off Press the power button After it beeps all of the buttons on the control panel along...

Страница 11: ...up the sensor sensitivity will become unstable Remove dust every two months or so Clean the dust sensor often when using in an environment with excessive dust Use a cotton swab or something similar t...

Страница 12: ...eplacement deodorizing dust collecting anti bacterial filters sold separately please refer to the model number in Accessories on page 13 and consult your dealer 5 Reset the filter replacement indicato...

Страница 13: ...ust collecting anti bacterial filter is installed properly and firmly close the cover 7 The odor and dust monitor remains red The dust and odor sensors may react to changes in temperature and humidity...

Страница 14: ...the indications of the odor and dust monitor The operation does not stop even though the air is clean The unit will continue to operate with a low air volume even if the room is clean The unit smell...

Страница 15: ...Width 242 Depth 242 Height 652 including protrusions Weight kg 6 3 including filter Power cord length m 1 8 Accessories Deodorizing dust collecting anti bacterial filter 2 instruction manual warranty...

Страница 16: ...JA 00001 0301 http en cado co jp...

Отзывы: