background image

7

Close the cover.

With the cover switch slid down, attach the cover onto the unit.

Jan.

1

2015

Note 

Again, make sure the top and bottom position of the filter is correct 

before attaching the cover.

3

Содержание AP-C200

Страница 1: ...ons 3 Installing the Unit 4 Parts and Functions 6 Installing the Deodorizing Dust Collecting Anti Bacterial Filter 8 How to Operate 9 Maintenance 11 Troubleshooting 13 Specifications Air Purifier AP C...

Страница 2: ......

Страница 3: ...ce center Do not use the unit in the following locations In areas with flammable gas or places with metal dust It may lead to the gas catching on fire igniting or fuming due to dust being sucked into...

Страница 4: ...o stop operation and unplug the power plug Leaving the power plug in the outlet may cause electric shock or injury Do not sit or stand on the unit Falling down from the unit or toppling may cause inju...

Страница 5: ...or malfunction of the unit Do not use the unit near a TV or radio It may cause distortion of video images or noise Place the unit at least 1m away from a TV or radio Also using the same wall outlet as...

Страница 6: ...ti bacterial filter removes the dust and odor particulates page 6 10 Odor and dust monitor indicates the room air quality in blue yellow and red page 5 Control panel page 8 Handle When carrying the un...

Страница 7: ...nd indicates the air environment in the room with the colors blue yellow and red Odor and dust monitor Air environment of room Blue Clean Yellow Slightly polluted Red Polluted Odor and dust sensors De...

Страница 8: ...cterial Filter 1 2 c Attach the Filter Start Date label on the filter Write the filter use start date on the label then attach it onto the side printed TOP on the filter XX XXXX XXXX Filter Start Date...

Страница 9: ...7 Close the cover With the cover switch slid down attach the cover onto the unit Jan 1 2015 Note Again make sure the top and bottom position of the filter is correct before attaching the cover 3...

Страница 10: ...cators and buttons on the control panel along with the odor and dust monitor will momentarily light up then turn off Press the power button After it beeps all of the buttons on the control panel along...

Страница 11: ...up the sensor sensitivity will become unstable Remove dust every two months or so Clean the dust sensor often when using in an environment with excessive dust Use a cotton swab or something similar t...

Страница 12: ...eplacement deodorizing dust collecting anti bacterial filters sold separately please refer to the model number in Accessories on page 13 and consult your dealer 5 Reset the filter replacement indicato...

Страница 13: ...ust collecting anti bacterial filter is installed properly and firmly close the cover 7 The odor and dust monitor remains red The dust and odor sensors may react to changes in temperature and humidity...

Страница 14: ...the indications of the odor and dust monitor The operation does not stop even though the air is clean The unit will continue to operate with a low air volume even if the room is clean The unit smell...

Страница 15: ...Width 242 Depth 242 Height 652 including protrusions Weight kg 6 3 including filter Power cord length m 1 8 Accessories Deodorizing dust collecting anti bacterial filter 2 instruction manual warranty...

Страница 16: ...JA 00001 0301 http en cado co jp...

Отзывы: