83
VENUS - GIOIA
EN
11.9
”FAILURE DEPRESS” ALARM
To the boiler is connected a pressostat which control the depression and in some stove models on the fire
door id installed a microswitch which registers the opening.
“ACTIVE ALARM” “AL 8 - FAILURE DEPRESS”: the pressostat and/or fire door which is not correctly closed
stops the power supply to the auger.
• Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”.
• Check the type of glitch as
ALARMS page 90
.
• Unscrew the black cap, press the button and screw the cap again.
• Clean the burning pot and start the stove up again with P4 key.
11.10
”OPEN DOOR” ALARM
On the lower part of the fire door is installed a microswitch which detects the opening.
“ACTIVE ALARM” “AL 9 - OPEN DOOR”: it means that the fire door is not correctly closed.
• Reset the error pressing P4 key. The stove carries out a “FINAL CLEANING” and “OFF” appears.
• Check the type of failure as shown on
ALARMS page 90
.
• Clean the burning pot and start the stove up again pressing P4 key.
12
MAINTEINANCE
12.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following
paragrafs.
•
Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have
your fume pipe, chimney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets
and the electronical elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance
Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume
exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be
cleaned and checked more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized
Retailer.
Before any movement let the fire inside the combustion chamber extinguish till the total
cooling and always disconnect the plug from the socket.
12.2
BURNING POT AND ASH TRAY CLEANING
The burning pot and ash tray cleaning must be executed at least every 2 days.
• Open the door.
Содержание GIOIA
Страница 2: ......
Страница 49: ...49 VENUS GIOIA IT 14 3 RICAMBI Fig 60 Ricambi ...
Страница 52: ...52 VENUS GIOIA IT 14 4 DICHIARAZIONE DI CONFORMITÀ Fig 61 Dichiarazione di Conformità ...
Страница 98: ...98 VENUS GIOIA EN 14 3 SPARE PARTS Fig 60 Spare parts ...
Страница 101: ...101 VENUS GIOIA EN 14 5 DECLARATION OF CONFORMITY Fig 61 Declaration of Conformity ...
Страница 148: ...148 VENUS GIOIA FR 14 3 PIÈCES DÉTACHÉES Fig 60 Pièces détachées ...
Страница 151: ...151 VENUS GIOIA FR 14 5 DÉCLARATION DE CONFORMITÉ Fig 61 Déclaration de Conformité ...
Страница 197: ...197 VENUS GIOIA ES 14 3 REPUESTOS Fig 60 Repuestos ...
Страница 200: ...200 VENUS GIOIA ES 14 5 DECLARACIÓN DE CONFORMEDAD Fig 61 Declaración de conformedad ...
Страница 247: ...247 VENUS GIOIA NL 14 3 RESERVEONDERDELEN Fig 60 Reserveinderdelen ...
Страница 250: ...250 VENUS GIOIA NL 14 5 CONFORMITEITSVERKLARING Fig 61 Conformiteitsverklaring ...
Страница 297: ...297 VENUS GIOIA PT 14 3 PEÇAS SOBRESSALENTES Fig 60 Peças sobressalentes ...
Страница 300: ...300 VENUS GIOIA PT 14 5 DECLARAÇÃO DE CONFORMIDADE Fig 61 Declaração de conformidade ...
Страница 348: ...348 VENUS GIOIA EL 14 3 ΕΞΑΡΤΗΜΑΤΑ Fig 60 Εξαρτήματα ...
Страница 351: ...351 VENUS GIOIA EL 14 5 ΔΗΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ Fig 61 Δηλωση Συμμορφωσησ ...