INDOOR UNIT PART IDENTIFICATION

HEA

T

COOL

TEMPERA

T

URE

RUN

DEHUMIDIFY

SIGNAL

RECEIVING

WINDOW

Display Closeup

Air intake

Air outlet

Drain Hose

Remote control holder

7

1

2

3

5

6

8

9

10

4

7

Front Panel Frame

Display Panel (shown for 40GXM units)*

Front Panel

Air Filter

Horizontal Airflow Louver

Manual Adjustable Vertical Airflow Louver

Remote Control

Room Temperature Sensor

Inter-Connecting Tubing

Control and Power Wiring to Indoor Unit

11

Service Valves

1

2

3

4

5

6

8

9

10

11

A12590

Indoor/Outdoor Unit

Содержание 38GVM

Страница 1: ... convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed __________...

Страница 2: ...h wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technical assistance service or repair i...

Страница 3: ...control holder 7 1 2 3 5 6 8 9 10 4 7 Front Panel Frame Display Panel shown for 40GXM units Front Panel Air Filter Horizontal Airflow Louver Manual Adjustable Vertical Airflow Louver Remote Control Room Temperature Sensor Inter Connecting Tubing Control and Power Wiring to Indoor Unit 11 Service Valves 1 2 3 4 5 6 8 9 10 11 A12590 Indoor Outdoor Unit ...

Страница 4: ...p and Down Buttons 5 Fan Speed 6 Horizontal Louver Swing Button 7 Clock Button 8 Timer ON Button 9 Dry Coil Button 10 Temperature Button 11 Timer OFF Button 12 Turbo Mode Button 13 Sleep Mode button 14 Light Button to Turn ON or OFF Display on Front Panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A12434 Remote Control 09k 18k ...

Страница 5: ...ning in AUTO mode 4 MODE DISPLAY Indicates the current operation mode AUTO COOL DRY FAN ONLY or HEAT 5 SLEEP DISPLAY Indicates unit is running in SLEEP mode 6 TEMPERATURE DISPLAY Temperature setting from 61_F 16_C to 86_F 30_C will be displayed If FAN mode is selected there will be no temperature displayed 7 CLOCK DISPLAY Indicates the current time 0 to 24 hours 8 CLOCK INDICATOR Displayed with ti...

Страница 6: ...press the button the time moves forward or backward by one minute de pending on which button you press If you push the or button continuously the time adjusts in increments of 10 minutes 3 When the right time is achieved press the CLOCK button once to set the time The will stop flashing 4 To readjust the Clock Press the CLOCK button on the remote The will flash Repeat steps 1 through 3 NOTE The ti...

Страница 7: ...nel will turn red and the remote control will display the setpoint and time OPER will disappear NOTE If the On Off button is pressed too soon after a stop the compressor will not start for 3 minutes due to the inherent protection against frequent compressor cycling When turning the unit ON and OFF the Timer and Sleep functions will be canceled SELECTING THE OPERATING MODE Use the MODE button to se...

Страница 8: ...dry modes to ensure that additional moisture is removed from coil Push the X FAN button to enable this feature This will be displayed on remote control OPER ºF ºC HOUR ON OFF Remote Dry Coil Icon A09637 To deactivate this feature push the X FAN button again Selecting the Horizontal Direction Louver Position When the unit is turned on the louvers default to the cooling or heating position If the lo...

Страница 9: ...will continue operating normally NOTE When the unit is shut off by the user using the ON OFF button and if the TIMER ON is set the following will be displayed on the remote control Set Point Time Clock indicator next to time indicates TIMER ON is set On the display panel the operation light will turn red When the TIMER ON set time is reached the display on the remote does not change but the unit w...

Страница 10: ...ing Features If the unit is in the heating mode there will be a delay when the fan starts The fan will start only after the coil is warmed up to prevent cold blow Defrost Operation In heating mode if the outdoor coil is frosted the indoor fan and outdoor fan will turn off while system removes the frost on the outdoor coil H1 will be displayed on the display panel on the front cover of the unit The...

Страница 11: ...may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If necessary a mild liquid detergent can be applied and wi...

Страница 12: ... call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller will delay the unit for 3 minutes before allowing the unit to start back up The circuit breaker has tripped or a fuse has blown Power failure Error codes displayed Voltage is too low After turning unit off wait at least 3 minutes before trying to restart Reset the ci...