38
OCPP 1.6J
–
OCPP variables
Variable
Default value
StopTransactionOnEVSideDisconnect TRUE
AuthorizationCacheEnable
FALSE
ConnectionTimeOut
0
MinimumStatusDuration
0
BlinkRepeat
0
LightIntensity
100
MaxEnergyOnInvalid
0
ResetRetries
1
MeterValuesSampledData
Energy.Active.Import.Register, Current.Import, Voltage
MeterValuesAlignedData
Energy.Active.Import.Register, Current.Import, Voltage
StopTxnAlignedData
Energy.Active.Import.Register
StopTxnSampledData
Energy.Active.Import.Register
ConnectorPhaseRotation
Unknown
8.2.12
Dynamic power management and load balancing
The load balancing menu allows to setup the dynamic power management and/or the load
balancing functionalities.
Note: the dynamic power management and load balancing functionalities need and external
meter or current transformer to work properly
Step
Description
Picture
1
Click on the configuration icon
(the top right icon in the red
circle).
Insert the user password (the
same used in the first-time
connection)