INSTALLATION
2-15
To implement a Split Hub configuration:
1.
Install a new TRMM-2 or clear NVRAM on one that is configured
and install it.
The “
Configure as SPLIT HUB or COLLAPSED BACKBONE?
y/[n]
” message appears.
2.
Press
Y
.
The “
Configure a SPLIT HUB allowing two Token Rings
to exist? y/[n]
” message appears.
3.
Press Y.
The “
Enter slot number which begins second ring? 2-8
”
message appears.
4.
Enter the slot number. (The second ring will begin at that slot.)
If you enter a slot that contains a port switching MIM, the “
INVALID
character [x]
” message appears. Re-enter a correct slot.
The “
Is this correct? y/[n]
” message appears.
5.
Press Y.
The “
Configuring as Split Hub
” message appears.
2.9 CONNECTING A UPS
The TRMM-2 can be used to monitor a UPS. It must be connected to the
UPS using a special DB9-to-RJ45 cable assembly available from
Cabletron Sales. See
Table D-5
for details about pinouts for the cable.