Diagnostic Procedures
2-13
Action:
None, unless If an RLP that you know is installed
did not load, in which case remove it and check the
switch settings to verify that it is configured cor-
rectly.
Memory Test (“n”):”n,” Requests “n,” Outstanding Size “n”
Meaning: This is part of normal IPL testing.
Action:
None.
No Database Present, Creating a Database for Release “n”
Meaning: Self-explanatory. During migration the first time a
node is booted with a new software release, a new
default database will be created.
Action:
Reconfigure all database files as necessary (see the
User Guide) or copy the old database to the hard
disk. (See
Chapter 3
.)
No remote subscribers for subID “n”
Meaning: No PU records existed in the database for the spec-
ified SNA subscriber (
subID
).
Action:
Delete the SNA Subscriber record or create the
missing PU records (described in the User Guide).
FRX6000 LAN driver returns error “n”, (29 means netbind was not run,
(mi.status)
Meaning: There was an IPL problem.
Action:
Shut down the node and check to assure proper
seating of the LAN card(s). If the error repeats on
rebooting, reinstall the FRX6000 software. (See
Appendix C
.)
FRX6000 LAN driver V”n”.”n” bound to “n” cards. (Mi.ProtMajor,
mi.ProtMinor, mi.numBound)
Meaning: The LAN driver was loaded to the cards.
Action:
None.
Output Device: VGA
Meaning: Self-explanatory.
Action:
None.
Содержание SPECTRUM FRX6000
Страница 1: ...0DLQWHQDQFH XLGH Document number 09 41 06 105 03 The Comp le te Net wo rking Solutio nTM...
Страница 2: ......
Страница 6: ...vi FRX6000 Maintenance Guide Rev 03...
Страница 9: ...ix List of Tables 2 1 BIOS Setup Parameters 2 18 B 1 RLP Addresses B 1...
Страница 10: ......
Страница 52: ......
Страница 62: ......
Страница 76: ......